DISPLAY
CAUSE
EFFECT
SOLUTION
NOTE
The volume counter has rea-
ched the number of litres of
deliverable water set during
programming phase.
Coffee will not be delivered;
the dose will not be halted or it
is variable.
Regenerate cleaning filter
salts. To erase the alarm see
paragraph on ‘RESETTING
CLEANING FILTER LITRE
COUNTER’.
This alarm will not halt
delivery. The cleaning fil-
ter alarm can be elimina-
ted by programming the
number of litres to zero
(see paragraph on
‘PROGRAMMING’)
CLEANING FILTER
ALARM
One of the two temperature
probes is broken.
Coffee will not be delivered.
Substitute the broken probe.
This alarm blocks all
deliveries.
TEMPERATURE PROBE
MALFUNCTION ALARM
Too much coffee.
Coffee will not be delivered
and an ejection cycle will be
effected.
Reduce the quantity of coffee. This alarm will not halt
delivery. The cleaning fil-
ter alarm can be elimina-
ted by programming the
number of litres to zero
(see paragraph on
‘PROGRAMMING’).
COFFEE QUANTITY
ALARM