40/46
7. CLEANING
• Depending on the measuring system‘s mounting attitude and the ambient conditions, it
may be necessary to clean the scale tape surface and sensor surface of the scanning
head (scanning window for counting and reference track) occasionally.
• If the monitoring signal output by the scanning head is used, the encoder indicates that
cleaning is necessary�
• When cleaning the components, ensure that the scanning window and scale tape are
not scratched by any deposited particles!
• Dirt should be removed using a soft brush or oil-free compressed air�
• Use cotton balls or a soft and lint-free rag for cleaning� Use a solvent if necessary (e�g�
Acetone or Alcohol).
• Avoid to contact the solvent and the adhesive tape! This could start to dissolve the
adhesive and reducing the adhesive force� Furthermore the scale tape can be detached
totally�
• Ensure that no solvent seeps under the scale tape! This could adversely affect the
adhesive layer between the scale tape and carrier tape, thereby loosening the scale
tape�
ATTENTION: Acetone and Alcohol are inflammable liquids!
Adjustment & Epiflex Tool Set
PWT 101 + NPA
Info
344220-33 together with 344220-70
OR 344220-90
PWT 101 + NPA
Show device Info
Yes (IdentNr&SN)
Yes (IdentNr&SN)
Online compensation
ON/OFF switchable
ON/OFF switchable
Relative counter value
No
Yes
Adjustment of incremental
signal
Yes (automatic/ manual)
No
Adjustment of Reference
signal
Yes (automatic/ manual)
Yes (only automatic)
Error check
No
Yes
Save/read function
Yes
No (just rewrite save only for RI
adjustment)
6.3. Comparison of the different adjustment variants
Chart 9