5.4
Mounting Steps
Hereafter the mounting steps for a LIKgo measuring system from NUMERIK JENA will be
described�
Please read the notes mentioned to the particular mounting steps thorough and follow the
indicated sequence of mounting steps exactly!
Step 1
• Preferably the tape should be mounted in a slot or along an edge�
• Please mark the future location of the scale tape before starting with the mounting�
• The alignment of the scale tape depends on the installation position of the scan head�
• Ensure that the scanning head‘s scanning fields for the counter and reference tracks are
over the corresponding tracks on the scale tape (see also image in 4.1.2)
ATTENTION: Acetone and Alcohol are inflammable liquids!
Mounting slot
Mounting edge
0,1 0,1
F
X/10
T
0,05
8,1
+0,1
≥8
T
X/10
0,1
0,1
F
0,1 0,1
F
X/10
T
0,05
8,1
+0,1
≥8
T
X/10
0,1
0,1
F
Accuracy class
X
±3 µm/m
0,009
±5 µm/m
0,009
Scale tape
T
SINGLEFLEX
0,5
-0�1
Image 15
F
Machine guideway
Содержание LIKgo