12
www.numatic.co.uk
After use, empty waste water tank using emptying hose and flush-out with
clean water.
Remove floor tool vacuum hose ensuring you remove the U-bend clip and flush out
with clean water.
Empty clean water tank, using emptying hose and again flush out with clean water.
A
B
C
Machine cleaning
ALWAYS ENSURE THAT THE MACHINE IS SWITCHED OFF PRIOR TO ANY MAINTENANCE.
!
!
A
B
C
Push in the 2 retaining handles of the separator.
Remove and clean vacuum shut off filter.
Remove large debris filter, clean and replace.
After cleaning, refit the separator and reconnect
the hoses.
Holding the handles lift the separator away.
Clean and examine rubber seal during
each clean.
Located in your waste water top tank is a vacuum shut off system, this prevents suction when the waste water tank is full.
It also prevents foam created by high-foaming detergents from entering the motor.
Sometimes the float vents get clogged and blocked, clean to ensure correct operation. Remove debris basket filter and rinse using
clean water, and refit.
Refit both of the vacuum hoses.
IMPORTANT: IF THE DEBRIS BASKET IS ALLOWED TO BECOME CLOGGED,
VACUUM PERFORMANCE CAN DETERIORATE.
!
!