Page 30
Troubleshooting - Control Valve
Problem
Cause
Correction
7. Excessive water in brine
tank.
A. Plugged drain line flow control.
A. Clean flow control.
B. Plugged injector system.
B. Clean injector and screen.
C. Timer not cycling.
C. Replace timer.
D. Foreign material in brine valve.
D. Replace brine valve seat and clean
valve.
E. Foreign material in brine line
flow control.
E. Clean brine line flow control.
8. Softener fails to draw brine.
A. Drain line flow control is
plugged.
A. Clean drain line flow control.
B. Injector is plugged.
B. Clean injector
C. Injector screen plugged.
C. Clean screen.
D. Line pressure is too low.
D. Increase line pressure to 20 P.S.I.
E. Internal control leak
E. Change seals, spacers, and piston
assembly.
F. Service adapter did not cycle.
F. Check drive motor and switches.
9. Control cycles continuously.
A. Misadjusted, broken, or shorted
switch.
A. Determine if switch or timer is faulty
and replace it, or replace complete
power head.
10. Drain flows continuously.
A. Valve is not programming
correctly.
A. Check timer program and positioning
of control. Replace power head assembly
if not positioning properly.
B. Foreign material in control.
B. Remove power head assembly and
inspect bore. Remove foreign material
and check control in various regeneration
positions.
C. Internal control leak.
C. Replace seals and piston assembly.
General Service Hints For Meter Control
Problem: Softener delivers hard water
Reason: Reserve capacity has been exceeded.
.
Correction:
Check salt dosage requirements and reset reserve capacity to provide additional reserve.
Reason: Meter is not measuring flow.
.
Correction on Mechanical Meter:
Check with meter checker kit. If volume is not registering, check the
.
meter cap and impeller for debris, and ensure they can move freely.
.
Correction for Electronic Meter:
Check for a short in the meter cable. Ensure that it is programmed as
.
a meter, and that the turbine and impeller can move freely.
Содержание 7000XTR
Страница 1: ...Model 7000XTR Service Manual IMPORTANT Fill in Pertinent Information on Page 3 for Future Reference ...
Страница 21: ...Page 21 Notes ...
Страница 22: ...Page 22 Power Head Assembly 61501 7000XT_REVA ...
Страница 34: ...Page 34 Brine Tank Refill Position 40988_REVA 41121_REVA Water Conditioner Flow Diagrams ...
Страница 38: ...Page 38 Dimensional Drawings 61500 7000XTR LNE_REVA ...
Страница 39: ...Page 39 Meter Flow Data TR18753 Softener TR18688 Filter 41140 02_REVA ...
Страница 40: ...Page 40 Injector Flow Data TR18755_REVB ...
Страница 41: ...Page 41 Notes ...
Страница 42: ...Page 42 Notes ...
Страница 43: ...Page 43 Notes ...
Страница 44: ...P N 42484 Rev A ...