OM0228
Page
14
of
99
February/2014
5.2.4
Gas
Service
NuAire
doesn't
recommend
the
use
of
natural
gas
within
the
LFBSC,
but
if
gas
service
is
determined
to
be
necessary
for
the
application,
appropriate
safety
measures
must
take
place.
All
NuAire
LFBSC's
have
precautionary
warning
labels
that
say
the
following:
Use
of
explosive
or
flammable
substances
in
this
cabinet
should
be
evaluated
by
your
appropriate
safety
personnel.
Once
the
appropriate
safety
personnel
have
made
the
determination,
the
application
of
natural
gas
must
be
performed
in
accordance
to
national,
state
and
local
codes.
IT
IS
ALSO
STRONGLY
RECOMMENDED
THAT
AN
EMERGENCY
GAS
SHUTOFF
VALVE
BE
PLACED
JUST
OUTSIDE
THE
LFBSC
ON
THE
GAS
SUPPLY
LINE.
All
NuAire
LFBSC's
meet
the
safety
requirements
of
UL
and
CSA
for
Laboratory
Equipment.
To
comply
with
these
safety
requirements,
NuAire
uses
only
certified
gas
valves.
In
addition,
if
external
piping
is
required,
only
black
pipe
is
used
for
this
application.
As
previously
stated
NuAire
doesn't
recommend
the
use
of
natural
gas
within
the
LFBSC
and
ASSUMES
NO
RESPONSIBILITY
FOR
ITS
USE.
USE
AT
YOUR
OWN
RISK.
The
Bunsen
burner
flame
within
the
LFBSC
not
only
contributes
to
heat
build
‐
up;
is
also
disrupts
the
laminar
air
stream,
which
must
be
maintained
for
maximum
efficiency.
IF
THE
PROCEDURE
DEMANDS
USE
OF
A
FLAME,
A
BUNSEN
BURNER
WITH
ON
DEMAND
IGNITION
IS
STRONGLY
RECOMMENDED.
DO
NOT
USE
CONSTANT
FLAME
GAS
BURNERS.
During
use,
the
Bunsen
burner
should
be
placed
to
the
rear
of
the
workspace
where
resulting
air
turbulence
will
have
a
minimal
effect.
5.2.5
Plumbing
Services
Service
ball
valves
with
the
type
of
service
specified
by
the
removable
button
on
the
handle
are
located
in
the
work
zone.
The
service
ball
valves
are
not
recommended
for
pressure
over
75
p.s.i.
(5.2
BAR).
Reducing
valves
should
be
installed
external
to
the
cabinet
if
necessary.
Service
ball
valves
should
never
be
used
for
flammable
gasses
or
oxygen
service.
A
special
needle
valve
for
oxygen
service
or
certified
valve
is
required
and
available
upon
request.
External
connection
is
to
3/8
inch
NPT
coupling
in
the
inner
sidewalls.
Connection
to
plant
utilities
should
be
made
with
proper
materials
for
the
individual
service
and
according
to
National
and/or
Local
codes.
Observe
all
labels
pertaining
to
the
type
of
service
and
operating
pressure.
Remote
controlled
needle
‐
valve
plumbing
fixtures
can
be
optionally
provided
within
the
interior
sidewalls.
Control
handles
are
located
externally
on
the
vertical
airfoil.
Service
outlets
within
the
interior
have
serrated
tapered
fittings
designed
for
hose
connections
with
the
remote
controlled
needle
valve
plumbing
fixtures.
NuAire
provides
for
rear,
bottom,
or
top
connections
of
plumbing
services
to
plant
utilities.
Connection
from
the
needle
valve
assembly
to
the
welded
exit
coupling
is
accomplished
with
the
supplied
3/8
inch
soft
copper
tubing
as
standard
(alternative
materials
to
meet
local
codes
are
available
upon
request).
The
needle
valves
are
not
recommended
for
working
pressure
in
excess
of
125
p.s.i.
(8.6
BAR).
5.2.6
Electrical
Services
The
NU
‐
430
series
Biological
Safety
Cabinets
may
be
"hardwired"
(optional)
or
plugged
into
an
outlet
with
protective
earthing
connection
with
the
standard
power
cord.
The
cabinet
requires
115VAC,
60Hz
single
phase
(correct
rating
varies
per
cabinet
size,
reference
Electrical/Environmental
Requirements).
It
is
recommended
that
power
to
the
cabinet,
whether
hardwired
or
plug
connected,
be
on
its
own
branch
circuit,
protected
with
a
circuit
breaker
at
the
distribution
panel
near
the
cabinet.
A
surge
protector
is
strongly
recommended
if
you
are
experiencing
power
related
faults.
PLEASE
NOTE
THIS
CABINET
CONTAINS
ELECTRONIC
BALLASTS
FOR
THE
FLUORESCENT
LIGHTING.
ELECTRONIC
BALLASTS
OPERATE
WITH
HIGH
INRUSH
CURRENT.
IT
IS
NOT
RECOMMENDED
TO
USE
THIS
PRODUCT
WITH
GROUND
FAULT
CIRCUIT
INTERRUPTERS
(GFCI'S)
BECAUSE
THE
BALLASTS
MAY
CAUSE
THE
GFCI
TO
TRIP.
CAUTION
!
Содержание Labgard NU-430-400
Страница 7: ...OM0228 Page 7 of 99 February 2014 ...
Страница 9: ...OM0228 Page 9 of 99 February 2014 ...
Страница 10: ...OM0228 Page 10 of 99 February 2014 ...
Страница 16: ...OM0228 Page 16 of 99 February 2014 ...
Страница 17: ...OM0228 Page 17 of 99 February 2014 ...
Страница 41: ...OM0228 Page 41 of 99 February 2014 ...
Страница 93: ...OM0228 Page 93 of 99 February 2014 ...
Страница 94: ...OM0228 Page 94 of 99 February 2014 ...
Страница 95: ...OM0228 Page 95 of 99 February 2014 ...
Страница 96: ...OM0228 Page 96 of 99 February 2014 ...
Страница 97: ...OM0228 Page 97 of 99 February 2014 ...
Страница 98: ...OM0228 Page 98 of 99 February 2014 ...
Страница 99: ...OM0228 Page 99 of 99 February 2014 ...