Nuaire | Western Industrial Estate | Caerphilly | CF83 1NA | nuaire.co.uk
BPS V-AT
Installation Manual
3.0 OPTIONAL ANCILLARIES
1
Typical Optional Ancillaries
Filter
Control Section
2 or 3
5
7
Filter
Plate heat exchanger or
thermal wheel module
6
1a
Extract module
Exhaust/intake
module
LPHW, DX or
chilled water
4
1
Electric Heater
Model shown is right hand
Quick Selection Guide BPS BOXER PACKAGED AHU’s - ANCILLARIES
BPS Unit
Module
Part
Number
Description
Attenuator
1
B**AV/AR900-R
BPS size **. Attenuator for Supply/Extract, Right Handed, for Vertical PHX Units.
B**AV/AR900-L
BPS size **. Attenuator for Supply/Extract, Left Handed, for Vertical PHX Units.
B**AT/AR900-R
BPS size **. Attenuator for Supply/Extract, Right Handed, for Thermal Wheel Units.
B**AT/AR900-L
BPS size **. Attenuator for Supply/Extract, Left Handed, for Thermal Wheel Units.
Attenuator
1a
B**AV/AA900-R
BPS size **. Attenuator for Intake/Exhaust, Right Handed, for Vertical PHX Units.
B**AV/AA900-L
BPS size **. Attenuator for Intake/Exhaust, Right Handed, for Vertical PHX Units.
B**AT/AA900-R
BPS size **. Attenuator for Intake/Exhaust, Right Handed, for Thermal Wheel Units.
B**AT/AA900-L
BPS size **. Attenuator for Intake/Exhaust, Right Handed, for Thermal Wheel Units.
Frost Coil - Electric
2
B**AV/FE-R
BPS size **. Frost Coil Electric, 36kW, Right Handed, for Vertical PHX Units.
B**AV/FE-L
BPS size **. Frost Coil Electric, 36kW, Left Handed, for Vertical PHX Units.
B**AT/FE-R
BPS size **. Frost Coil Electric, 36kW, Right Handed, for Thermal Wheel Units.
B**AT/FE-L
BPS size **. Frost Coil Electric, 36kW, Left Handed, for Thermal Wheel Units
Frost Coil - LPHW
3
B**AV/FL-R
BPS size **. Frost Coil LPHW, Right Handed, for Vertical PHX Units.
B**AV/FL-L
BPS size **. Frost Coil LPHW, Left Handed, for Vertical PHX Units.
B**AT/FL-R
BPS size **. Frost Coil LPHW, Right Handed, for Thermal Wheel Units.
B**AT/FL-L
BPS size **. Frost Coil LPHW, Left Handed, for Thermal Wheel Units.
Recirculation Module
4
B**AV/RM-R
BPS size **. Recirculation Module, Right Handed, for Vertical PHX Units.
B**AV/RM-L
BPS size **. Recirculation Module, Left Handed, for Vertical PHX Units.
B**AT/RM-R
BPS size **. Recirculation Module, Right Handed, for Thermal Wheel Units.
B**AT/RM-L
BPS size **.Recirculation Module, Left Handed, for Thermal Wheel Units.
Weather Terminal
5
B**AV/RT
BPS size **. Weather Terminal, for Vertical PHX Units.
B**AT/RT
BPS size **. Weather Terminal, for Thermal Wheel Units.
Inlet/Outlet Damper
6
B**AV/D
BPS size **. Inlet/Outlet Dampers suitable for right or left handed Vertical PHX Units.
B**AT/D
BPS size **. Inlet/Outlet Dampers suitable for right or left handed Thermal Wheel Units.
Weather Terminal &
Inlet/Outlet Damper
7
B**AV/RTD-R
BPS size **. Weather Terminal & Damper, Right Handed, for Vertical PHX Units.
B**AV/RTD-L
BPS size **. Weather Terminal & Damper, Left Handed, for Vertical PHX Units.
B**AT/RTD-R
BPS size **. Weather Terminal & Damper, Right Handed, for Thermal Wheel Units.
B**AT/RTD-L
BPS size **. Weather Terminal & Damper, Left Handed, for Thermal Wheel Units.
** Insert BPS unit size sizes for the relevant ancillary.