MGN 2800N HP 13
LANDIS & STAEFA SKP75 VALVE ACTUATOR
2
3
4
5
6
1
Adjustment Description
1
Adjustment and indication
of the gas/air ratio (main
Flame setting)
2
Adjustment and indication
of the parallel
displacement of the
characteristic (Low Flame
setting)
3
Vented to atmosphere
4
Connection to the gas line
5
Connection to the
combustion air supply at
the burner head
6
Valve stroke indicator
Valve Adjustment Diagram
(air/gas ratio valve and regulator)
FRONT VIEW
REAR VIEW
AIR DAMPER MOTORS – H/L
9 8 7 6 5 4 3 2 1 N
Berger Lahr STM 30 B2
Berger Lahr
STM 30 Q5
Note:
The fully closed cam is factory set, and under normal
circumstances should not require further adjustment.
Operation of the low and high flame air switches is made by
manually adjustable cams. A setting scale is provided at the
end of the cam stack for guidance, while adjustments are
made using the screw adjusters situated within the cam disk
body (STM30 Q5), or with levers and fine setting screw
adjusters (STM30 B2).
Motor
STM30 B2
STM30 Q5
Air Damper
Position
Cam
Factory
Setting
Cam
Factory
Setting
Full Air
Shut-off
II 0° 1 0°
Low Flame
Air
V 15° 2 15°
High Flame
Air
I 60° 3 60°