13.5 - PREPARING THE FLUE 

a.  

The Flue Length supplied caters for a Maximum Flue Length of 500mm, 

      and a Minimum Flue Length of 93mm. 
   (Total Flue Length Including Terminal = 630mm). 

b. 

  To find the flue length required in your application

measure the  

      Depth from the front face of the Fireplace to the Outside Wall. For the 
      Fire with Sealing Frame deduct 343mm or without Sealing Frame deduct  
     359mm (ref page 9) from this dimension;  this will provide the flue length 
     for your application.  
    Take your flue length dimension from 500mm, (maximum wall flue   
     length provided), and this is the length you will need to cut off the flue.  
     See Diagram with Example. 

c. 

  From the open end of the flue mark the cut off dimension, position the 

 

cutting aid in the flue central about the cut line and cut the flue,  

 

ensuring it is cut square; remove any sharp edges.  

     Remove the Cutting Aid Material from inside the Flue. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
d. 

 With the flue at the correct length and when the fire is fitted there should be 130mm of Flue Terminal Outside The Wall and the 

 

screw holes for fixing the Wall Plate should line up with those in the Flue Terminal.  See photograph on next page. 

 

     ! IMPORTANT NOTE !   

NONE OF THE SQUARE HOLES IN THE FLUE TERMINAL MUST BE WITHIN THE WALL

 

  ! TIP ! 

To provide a good square cut end to the flue, working form the Open end of the flue; place 5 marks around the flue  

 

 

and using a tape measure coiled around the flue mark a continuous line.  

 

  ! IMPORTANT NOTE !  

Numerous problems occur because the cutting aid is not removed after cutting the flue.

 

 

  ! IMPORTANT NOTE !  

Numerous problems occur because the correct length of the flue is not first determined and the  

 

 

 

 

 

square cut outs in the flue terminal are not outside the flue. Check that the Wall Plate screws can    

 

 

 

 

be fitted into the Flue.  

 

     ! IMPORTANT NOTE !    

Do NOT FORCE the flue when engaged into the flue spigot; it goes in just 40mm up to a stop  

                                                        and will block off the flow creating a poor flame picture and overheating if pushed in too far.  

 

 
 

 

FLUE LENGTH DIAGRAM - EXAMPLE 

Depth for Fire used with the Sealing Frame = 343mm

 

Inside Wall to Outside Wall Dimension = 595mm 
Deduct the Appropriate Fire Depth:  
595mm – 343mm = 252mm 
 

Take this from the 500mm Flue Length Supplied:  
500mm – 252mm = 248mm. 
Cut 248mm off the Open End of the Flue  

NOTE: The Depth of the Fire can be different . 

 

Check Which Application Applies on Page 9.

 

Содержание Synergy Perspective BF

Страница 1: ...MPORTANT NOTE THIS FIRE IS HEAVY AND ASSISTANCE SHOULD BE SOUGHT WHEN LIFTING ALL INSTRUCTIONS MUST BE LEFT WITH THE USER FOR SAFE KEEPING MANUFACTURED by Nu Flame Limited Unit 4 Kimpton Trade Busines...

Страница 2: ...toms Possible Cause 34 21 Energy Class Product Fiche EU Declaration of Conformity 36 22 Diagram of Radio Frequency Control System 39 Guarantee 40 INSTALLATION OPTIONS 12 Sections 12 13 14 15 are for t...

Страница 3: ...ergy Glass has been ordered the Glass Shelf will also have been supplied with the Sealing Frame Important Store the Trims and Doors in a safe secure area as all parts will have been Quality Control ch...

Страница 4: ...the simulated logs or simulated bark chips need renewing please obtain suitable replacements from a Nu Flame Stockist u The fire must be installed in accordance with the rules in force and these Instr...

Страница 5: ...no nearer than 300mm to an opening in the building fabric formed for the purpose of accommodating a built in element such as a window frame The reference to external corners does not apply to building...

Страница 6: ...nked by arrow Please note that you can have the flame height anywhere between maximum and preset low For fine adjustment simply tap the large and small flame buttons d Switching Off Press the red off...

Страница 7: ...esent room temperature the fire will go straight to the Standby Setting until the temperature drops below the Set Temperature at which point the main burner will relight Note The Room Temperature is s...

Страница 8: ...re is not working and the Basic Reset has not worked a Full Reset can be carried out Open the outer door by pulling at the left side to release it from the magnetic catches and open the outer door loc...

Страница 9: ...te the Warranty IMPORTANT BEFORE PROCEEDING WITH THE INSTALLATION READ THESE INSTRUCTIONS CAREFULLY THESE INSTRUCTIONS SHOULD BE LEFT WITH THE USER FOR SAFE KEEPING AND FUTURE SERVICING PRIOR TO INSTA...

Страница 10: ...de Views show how far the Trims project from the wall Minimum Flat Sizes for Doors Frames Central Around Opening Width mm Height mm Synergy Perspective BF Steel Trim No Sealing Frame 1135mm 560mm Syne...

Страница 11: ...as been supplied for the correct gas to be used by checking the Data Badge in the base of the fire d A route for a concealed gas supply is provided through a hole in the rear of the fire at a position...

Страница 12: ...evisions With Options Above Note The Steel Trim Option Cannot Be With A Wall Mounted Installation However It Can Be Used In A Fire Surround Installation With A Fire Surround Installation the Shelf of...

Страница 13: ...aterial set at least 50mm away from the Fire Note A drip weather shield or equivalent should be provided above the Fireplace Enclosure to prevent rain damp bridging the cavity h A Hole for the flue sh...

Страница 14: ...Sealing Frame deduct 359mm ref page 9 from this dimension this will provide the flue length for your application Take your flue length dimension from 500mm maximum wall flue length provided and this i...

Страница 15: ...flange of the Sealing Frame stay in position to create a seal to the wall around the fireplace opening While sliding the unit into the Fireplace Opening pull on the excess cable j Referring to the ill...

Страница 16: ...ON 15 ARRANGEMENT OF THE FUEL EFFECT FIREPLACE ENCLOSURE HOLE CENTRES FOR CABLE FIXING SYSTEM EYEBOLTS NOTE Tensioning nut wound fully back to allow maximum adjustment FINISHED ADJUSTED Do not overtig...

Страница 17: ...ructural survey may be Required d For Combustible Installations e g Wood Studwork the Fireplace should be lined with a suitable non combustible material e g Superlux Board or Equivalent If the rear wa...

Страница 18: ...e hot Therefore we do not recommend any shelves space away from the slips 13 4 CUTTING THE HOLE FOR THE FLUE The flue is 150mm in diameter and a hole is required providing sufficient clearance The fol...

Страница 19: ...hould line up with those in the Flue Terminal See photograph on next page IMPORTANT NOTE NONE OF THE SQUARE HOLES IN THE FLUE TERMINAL MUST BE WITHIN THE WALL TIP To provide a good square cut end to t...

Страница 20: ...ips on the underside of the front of the Fire and the rear of the Fire outer frame stay in position to make a seal against the top edge of the slip at the base of the fireplace enclosure and the front...

Страница 21: ...OLE CENTRES FOR CABLE FIXING SYSTEM EYEBOLTS NOTE Tensioning nut wound fully back to allow maximum adjustment FINISHED ADJUSTED Do not overtighten just enough to seal 13 7 PROCEED TO SECTION 15 ARRANG...

Страница 22: ...and 150mm either side 1080mm minimum hearth width e The base of the fireplace must be flat level and square to the face of the fireplace opening f There can be no up stand around the hearth as the doo...

Страница 23: ...sure or fireplace as this can affect the fires efficiency and cause wall staining 14 4 CLEARANCES TO SHELVES COMBUSTIBLE MATERIALS Refer to diagram FIREPLACE CONSTRUCTION on previous page a A non comb...

Страница 24: ...hould line up with those in the Flue Terminal See photograph on next page IMPORTANT NOTE NONE OF THE SQUARE HOLES IN THE FLUE TERMINAL MUST BE WITHIN THE WALL TIP To provide a good square cut end to t...

Страница 25: ...ips on the underside of the front of the Fire and the rear of the Fire outer frame stay in position to make a seal against the top edge of the slip at the base of the fireplace enclosure and the front...

Страница 26: ...LE CENTRES FOR CABLE FIXING SYSTEM EYEBOLTS NOTE Tensioning nut wound fully back to allow maximum adjustment FINISHED ADJUSTED Do not overtighten just enough to seal 14 8 PROCEED TO SECTION 15 ARRANGE...

Страница 27: ...Breast will occur e The Wall Mounted Television must be mounted on a suitable bracket or angled bracket that meets the Television Manufacturer s requirements and spaces the Television at least 35mm a...

Страница 28: ...Gas Fires d The preferred height position for a Wall Mounted Television Must meet the Installation Requirements of these Instructions e The Nu Flame Television Glass Heat Shield is only suitable for t...

Страница 29: ...the Fire s Installation Instructions and the Fire Surround meets the Minimum Dimensions as detailed in the Diagrams Below b You Must take account of the Television Manufacturer s Installation requirem...

Страница 30: ...ly place natural coloured vermiculite granules from large bag into the central tray area on the burner sufficient to fill it to the top 5mm depth Secondly sprinkle a small quantity of black vermiculit...

Страница 31: ...n the log support at the front k Place log No 5 next to log No 6 locating it on the peg and the cut out in the rear log l Place the last log No 4 so that it locates on the central peg and rests in the...

Страница 32: ...l track down even a single strand of Embaglow and prevent the spark from arcing to the pilot p Before sealing the glass outer door with the 2 screws and the Pozidriv screwdriver provided check the con...

Страница 33: ...s the fire may stop working f The customer should be briefed on the need for regular servicing this will normally be once a year g Advise the customer that apart from batteries there are no user repla...

Страница 34: ...Embaglow material is left close to the pilot The spark from the ignition system will track down even a single strand of Embaglow and prevent the spark from arcing to the pilot j Check the Condition o...

Страница 35: ...as this could be the least cost option 20 5 PILOT FLAME SHORTENS OR GOES OUT WHEN MAIN BURNER IS SELECTED a Monitor the supply pressure at the isolation elbow as the main burner lights If pressure dr...

Страница 36: ...imum 67 5 The fire must be Installed serviced by a properly qualified in accordance with Local National Codes Installation Engineer and in accordance with these Installation Instructions Supplier Nu F...

Страница 37: ...9 The fire must be Installed serviced by a properly qualified in accordance with Local National Codes Installation Engineer and in accordance with these Installation Instructions Supplier Nu Flame Li...

Страница 38: ...BF Certificate Number CE688456 The object of the declaration described above is in conformity with relevant harmonized legislation Gas Appliance Regulation EU 2016 426 The following harmonised standar...

Страница 39: ...39 22 0 DIAGRAM OF RADIO FREQUENCY CONTROL SYSTEMS...

Страница 40: ...return delivery to us We will not be liable for any such breakages or losses Under no circumstances should any attempt be made to repair the burner on site without our express knowledge and approval d...

Отзывы: