![NTI AG LinMot E14 0 Series Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/nti-ag/linmot-e14-0-series/linmot-e14-0-series_installation-manual_1715277016.webp)
E1400 Installation Guide
preliminary
7 Error Codes
Error Codes
Error
Warn
EN
Description
Off
Warning
Operation
Enabled
Normal Operation:
Warnings and operation enabled are displayed.
On
●
~2Hz
0..15 x
Error Code
High Nibble
●
~2Hz
0..15 x
Error Code
Low Nibble
Error
:
The error code is shown by a blink code with “WARN” and “EN”.
The error byte is divided into low and high nibble (= 4 bit).
”WARN” and “EN” are blinking together.
The error can be acknowledged.
(e.g.: WARN blinks 3x, EN blinks 2x; Error Code = 32h)
●
~2Hz
●
~2Hz
0..15 x
Error Code
High Nibble
●
~2Hz
0..15 x
Error Code
Low Nibble
Fatal Error
:
The error code is shown by a blink code with “WARN” and “EN”.
The error byte is divided into low and high nibble.
”WARN” and “EN” are blinking together.
Fatal errors can only be acknowledged by a reset or power cycle.
(e.g.: WARN blinks 3x, EN blinks 2x; Error Code = 32h)
●
~4Hz
●
~2Hz
0..15 x
Error Code
High Nibble
●
~2Hz
0..15 x
Error Code
Low Nibble
System Error:
Please reinstall firmware or contact support.
●
~0.5Hz
●
~0.5Hz
On
Signal Supply 24V too low:
The error and warn LEDs blink alternating if the signal 24V (X4.2) is
less than 18VDC.
The meaning of the error codes can be found in the
Usermanual_MotionCtrl_Software_SG5 and the user manual of the installed
interface software. These documents are provided together with LinMot-Talk
configuration software and can be downloaded from
www.linmot.com
.
Page 16/24
www.LinMot.com
NTI AG / LinMot
®