NTI AG LinMot E1000 Series Скачать руководство пользователя страница 11

Controller Series E1000/2000/4000  

NTI AG  

Installation: E1000/E2000/E4000 series / 16.09.2005 

Page 11/12 

 

Declaration of Conformity CE-Marking 

 

Manufacturer:  

NTI 

AG 

 

 

 

LinMot 

®

 

  Technoparkstrasse 

   8005 

Zurich 

  

   Switzerland 
 

 

 

Tel.:  

+41 (0) 1 445 22 82   

 

 

 

Fax:  

+41 (0) 1 445 22 81 

 
Products:  

LinMot 

®  

Controllers 

 

Type Art.-No. 

Type Art-No. 

Type Art.-No. 

E1000-AT  0150-1605 E1000-MT  0150-1615  

 

E2000-AT  0150-1606 E2000-MT  0150-1616  

 

E4000-AT  0150-1608 E4000-MT  0150-1618  

 

E1000-DN  0150-1645 E1000-CO 0150-1673  

 

E2000-DN  0150-1646 E2000-CO 0150-1674  

 

E4000-DN  0150-1648 E4000-CO 0150-1676  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
The product must be mounted and used in strict accordance with the installation instruction contained 
within the User’s Manual, a copy of which may be obtained from NTI Ltd.  
 
I declare that as the authorized representative, the above information in relation to the 
supply/manufacture of this product is in conformity with the stated standards and other related 
documents in compliance with the protection requirements of the EMC Directive (89/336/EEC) and is 
marked in accordance with the CE Marking Directive (93/68/EEC). 
 
Standards Complied with: 
 

EMI 

EN 55011  

Class A 

EN 61000-6-4 

 

 

Electromagnetic 

EN 61000-4-2 

4 kV / 8kV 

Suspectibility EMC 

EN 61000-4-4 

1 kV / 2kV 

EN 61000-6-2 

EN 61000-4-3 

10 V/m 

 

EN 61000-4-6 

10 V 

 

ENV 50204 

10 V/m 

 
Company 
NTI Ltd. 
 
Zürich, February 24, 2003 
 

 
----------------------------------------------------------- 
R. Rohner  / CEO NTI Ltd.

 

Содержание LinMot E1000 Series

Страница 1: ...O E2000 AT MT DN CO E4000 AT MT DN CO Content IMPORTANT NOTES FOR E1000 E2000 E4000 SERIES CONTROLLERS 2 SYSTEM OVERVIEW 3 E1000 SERIES FUNCTION AND WIRING 4 POWER SUPPLY AND GROUNDING 5 DESCRIPTION O...

Страница 2: ...llers Do not switch Power Supply DC Voltage All power supply switching and E Stop breaks should be done to the AC supply voltage of the power supply Do not connect or disconnect the motors from contro...

Страница 3: ...ower Supply Motor 48 72 V From AC Mains 1x115V AC 1x230V AC RS232 Interface to PC for Configuration Linear Motor with internal Position Feedback Power Supply Signal 24 48 V Interfaces to PLC or PC Int...

Страница 4: ...Fuse Emergency Stop Breaker 48 72VDC Power Supply motor PWR motor GND 10 AT 0 5 AT signal components 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 5 4 3 2 1 9 8 7 6 1 11 Emergency Stop 6 1 7 2 12 8 3 13 14 15...

Страница 5: ...n order to assure a safe and error free operation and to avoid severe damage to system components all system components must be well grounded to either a single earth or utility ground This includes b...

Страница 6: ...Supply voltage for PWR Signal and PWR Motor may be different Motor Supply GND must be externally connected to earth Caution By exceeding 53VDC Power Supply Signal the controller will go into error st...

Страница 7: ...s by your own double check motor wiring carefully before power up Do not connect or disconnect the motors from controllers with voltage present Wait to connect or dis connect motors until all LinMot c...

Страница 8: ...put resistance 100kOhm for logical zero 2V for logical one 3 5V Dig Outputs Dig Out 6 Pos Error Out MSG Error Out Warn Out Dig Out 5 Open Collector max 24V 50 mA Typical pull up Resistor R for V 5V su...

Страница 9: ...es 16 09 2005 Page 9 12 Mechanical Dimension Dimensions 295 64 90 330 179 Centers 315 Fixings for 2 x M5 screws Recommended mounting for multiple controller installation Fixings for 2 x M5 screws LinM...

Страница 10: ...8 V 10 W Regeneration of Power The Exxxx controller don t use a regeneration resistor In most application the recuperated energy will not become an issue In cases where the motor power supply voltage...

Страница 11: ...e mounted and used in strict accordance with the installation instruction contained within the User s Manual a copy of which may be obtained from NTI Ltd I declare that as the authorized representativ...

Страница 12: ...supply voltage for the Power circuitry is too low 3x l l l l The supply voltage for the Power circuitry is too high 4x l l l l The supply voltage for the Signal circuitry is too low 5x l l l l The sup...

Отзывы: