LinMot Installation Guide C1100
7.8 X19
X19
System
1
2
3
4
5
6
7
8
case
(Do not connect)
(Do not connect)
RS232 Rx
GND
GND
RS232 Tx
(Do not connect)
(Do not connect)
Shield
RJ-45
Use Adapter cable
AC01-RJ45/Df-2.5-RS1 (Art.-No. 0150-2143)
for Configuration over RS232.
7.9 X33
X33
Safety Relays (only with the -1S option)
4 / 8
3 / 7
2 / 6
1 / 5
Ksr +
Ksr -
Ksr f+
Ksr f-
Safety Relay 1 / 2 Input positive
Safety Relay 1 / 2 Input negative
Safety Relay 1 / 2 feedback positive
Safety Relay 1 / 2 feedback negative
Spring cage connector
(has to be ordered
separately: see chapter
- Use 60/75°C copper conductors only
- Conductor cross-section max. 1.5mm
2
- Stripping length: 10mm
- Never connect the safety relays to the logic supply of the drive!
7.10
S1 - S2
S1 - S2
Address Selectors (on GP drives only)
S1 (5..8)
S2 (1..4)
Bus ID High (0 … F). Bit 5 is the LSB, bit 8 the MSB.
Bus ID Low (0 … F). Bit 1 is the LSB, bit 4 the MSB.
The use of these switches depends on the type of fieldbus which is used. Please see the corresponding
manual for further information.
NTI AG / LinMot
®
www.LinMot.com
Page 14/27