background image

Machine Inspection

1. 

Now that the machine is unpacked, remember to 

recycle all the packing materials.

2.  Inspect the machine for damage or missing 

components. If damage is found, contact the local 

freight company to file a claim.

• 

Located in the far left side of the control panel is the 

Power Switch

. The toggle switch is in the “OFF” 

position when it is down and is in the “ON” position 

when it is up. When turned on, the pump will turn on 

and pressurize the system. Note: the Power Switch 

will not work unless the Circuit Breaker is in the reset 

(lower, locked) position.

• 

Located next to the Power Switch is the 

Circuit 

Breaker 

The circuit breaker is rated for 10 amps. 

The machine is shipped with the circuit breaker in the 

“Disconnected” or tripped position. The circuit breaker 

is reset by depressing the plunger until is click in to the 

lower, locked position.

• 

The 

Battery Meter

 is located in the center of the 

control panel. The battery meter is a 10 segment LED 

display. When fully charged, the right most LED will 

be illuminated. As the battery discharges, the LED 

will move to the left indicating a 10% lower amount of 

battery charge. When the battery is 70% discharged 

the 2nd LED segment from the left will be flashing. 

When the battery is 80% discharged, the two left most 

LEDs will flash. See the section on Battery Charging 

for further instructions.

• 

Pump Pressure Control

 is to the right of the Battery 

Meter. The pump pressure control varies the speed of 

the pump. This will decrease or increase the pressure 

and flow of the pump. To decrease the pressure/

flow, turn the control knob counter clockwise. To 

increase the pump pressure/flow, turn the control knob 

clockwise.

• 

Spray Bar Switch

 is located on the right-hand side 

of the control panel. To turn the spray bars on, flip this 

switch to the “UP” position. Note: The spray bars will 

not work unless the Power Switch is “On”, powering 

the pump.

Solution Pump - 

The solution pump is a self-priming 60 

PSI pump. It has a pressure switch that will shut off when 

the pressure reaches 60 psi. The pump will turn back on 

when the pressure drops below 45 psi. 

In-Line Screen - 

The solution pump is protected from 

debris that may enter the solution tank by an in-line filter 

screen. The solution screen is located under the machine 

near the back. There is a ball valve just ahead of the In-

line screen. To clean the screen, shut the ball valve and 

unscrew the clear plastic sight glass. The screen can be 

removed and rinsed under running water. Replace the 

screen and re-install the sight glass. Open the ball valve to 

allow water to flow from the solution tank to the pump. 

Center Spray Bar - 

The center spray bar contains two 

spray tips that spray in an overlapping fan shape. Each tip 

will flow 0.1 GPM of solution when the pump is at 40 PSI 

running pressure (nominal.) To turn on the Center Spray 

Bar, turn on the Power Switch and the Spray bar Switch.

Unpacking Instructions

1.  Carefully cut the two (2) bands from around the carton. 

2. 

Remove the staples and open the top flaps.

3.  Remove the staples from the bottom of the carton 

attached to the pallet.

4.  Remove the carton.

5. 

Locate the small box under the machine, remove from 

the pallet and set aside.

6. 

One at a time, unbolt the front axle bolt and remove 

the lag screws holding the pallet mounting bracket. 

Reinstall the first axle bolt before working on the 

second side. -This will free the machine from the 

pallet. 

7. 

Locate the rear of the machine where the handle is 

located.

8. 

Use the handle to back the machine off the pallet, 

lifting the caster wheels off the pallet and setting them 

on the floor.

9. 

Once the caster wheels are on the floor, press down 

to pivot the machine’s weight onto the caster wheels, 

lifting the 10” wheels off the pallet.

10. Back the machine up until the 10” wheels are clear of 

the pallet. Set all the wheels on the ground.

11. 

Remove and read all operation instructions. 

12. 

Switch the circuit breaker to the “ON” position on the 

control panel.

13. 

Recycle the carton and pallet.

Intended Use 

The Opti-Mist 20B is intended for commercial use, for 
spraying of liquid solutions on level floors in an indoor 

environment, for example in hotels, schools, hospitals, 

factories, shops, offices and retail businesses.  The 

spraying settings can be adjusted to suit the spraying task.  
Water quantity, pump pressure, walking speed and solution 
concentration can be adjusted by the user.

Machine Components

Solution Tank - 

The solution tank is the plastic tank body. 

It has a capacity of 

20 gallons (75 liters.)

Control Panel - 

The operator control panel is located at 

the upper rear area of the machine. Operator controls are 

positioned for ease of use, and include icons for simplified 

user training. This panel has components that control 

various machine functions:

Содержание Opti-Mist 20B

Страница 1: ...OPERATION MANUAL Opti Mist 20B Wide Area Sprayer...

Страница 2: ...er inconsistent with its label If using a disinfectant be sure to follow the chemical manufacturer s instructions regarding dilution coverage and dwell time Use personal protective equipment as detail...

Страница 3: ...if not attended NEVER spray this machine with water or any liquids NEVER allow the battery charging plug to get wet or a short may occur NEVER allow this machine to be used as a toy Close attention is...

Страница 4: ...soap and water EYES Flush with water for 15 minutes or until irritation ceases INTERNAL Drink water or milk Follow with Milk of Magnesia beaten egg or vegetable oil Call a physician immediately Conte...

Страница 5: ...amage to property Electrical shock hazard Read the Operator Manual No smoking open flames or sparks near the batteries Batteries acid and hydrogen gas Poison Causes severe burns Avoid contact Recycle...

Страница 6: ...must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances The green conductor in the cord is the ground wire Never connect t...

Страница 7: ...e back There is a ball valve just ahead of the In line screen To clean the screen shut the ball valve and unscrew the clear plastic sight glass The screen can be removed and rinsed under running water...

Страница 8: ...4 Spray wand at the same time as any combination of spray bars To use the Spray wand 1 Plug the spray wand quick connect into the mating quick connect adapter in the center basket area of the machine...

Страница 9: ...of 25 vinegar and water overnight to remove any solution residue Clean the 100 mesh screen that is installed in the wand by rinsing it in running water Then place it in the vinegar solution with the...

Страница 10: ...head or replace Solenoid valve will not open Replace solenoid valve Solution tank filter plugged Remove obstacle or replace Pump Motor Will Not Run Motor shorted out Replace motor Faulty pressure swi...

Страница 11: ...start the charging process Flashing Red LED at start up indicates one of the two WET charging curves Flashing Green LED at start up indicates one of the two AGM GEL charging curves If the battery is...

Страница 12: ...olypropylene 4993171 Spray Tip Spray Wand 4993181 Front End Adapter 4993191 Tip Retainer Nut 4993281 25FT Black Spray Gun Hose w Female Quick Connect 4993611 Filter In line Strainer 100 ALWAYS USE GEN...