4.1.2 IMPORTANT NOTICE
a.
The water sensor switch has two contacts exposed in air. The unexpected seawater or rainstorm at
sea may make two contacts conducting. Even though, the magnetic bar on the ejector will keep the
beacon from being activated. So, it’s very important to place the beacon in the container in proper
direction and keep the container closed always, except for regular test or maintenance.
b.
If false alert is activated, please carry out the following procedures to cancel:
-
Inform nearest rescue organizations, as soon as possible, to stop all rescue service.
-
Open the switch cover and slide the switch to READY position to turn off the beacon.
-
In case the beacon can’t be turned off, remove or bend the antenna and put the beacon into a
sealed metal case for more than 10 days until the battery is exhausted. Consult the local agent
for service.