NGT-200 USER MANUAL
NGT-200 UM.E 20210520-02
50
6
TEST RESULTS
6.1
VIEW PROFILES MENU
This menu allows viewing all data stored in non-volatile memory. All the
measurements data is stored in 100 profiles (memory cells). Use
◄ ►
and
▲ ▼
keys to navigate the profiles.
An example of saved measurement results of a VHF radio station with DSC:
FIRST SCREEN:
Pr: 3
– profile number (for example);
15:40
– measurement time;
02/08/2017
– measurement date;
MMSI: 413900000
– tested station MMSI;
Format:
format specifier;
Categ:
received message category;
CRC:
CRC check result of received
message;
To:
receiver (Tester) MMSI number;
↓↑
:
clue to navigate the screens;
<VHF DSC>
: measurement mode mark.
SECOND SCREEN:
Pow:
signal power level, received on
channel 70;
Frq:
carrier frequency of channel 70.
Pr:3 15:40 02/08/17
MMSI: 413900000
Format: Individual
Categ: Safety
CRC: OK
To: 413999997
↓↑
<VHF DSC>
Pr:3 15:40 02/08/17
Pow: 43,7 dBm
Frq:156525070 Hz
SHIP: 1
↓↑
<VHF DSC>