NGT-200 USER MANUAL
NGT-200 UM.E 20210520-02
10
5.1.2 TEST VHF > RECEIVE DSC
After reception of the message
following information will appear
on the screen:
By entering this menu Tester is ready to
receive
Test
or
Distress
DSC message on
channel 70 with frequency 156525 kHz.
Tester is capable to receive DSC message
of category
Individual call
addressed to the
radio station specified by MMSI code.
Att: 20 dB
– set the internal attenuation
level in range 0…93 dB.
Attenuation will be taken into account
during estimation of the received signal
level.
X
– signalizes the selected measurement
configuration.
FIRST SCREEN of measurements:
MMSI: 413000000
– sender’s MMSI
code;
Format: Individual
– format specifier:
Individual call
(120);
Categ: Safety
–
category
Safety
(108);
CRC : OK
– control sum;
To : 413999997
– receiver’s MMSI
code;
Save –F2 Prof:x
↓↑
- to save received information to memory
in selected profile press
F2
; profile number
is set up automatically;
- to receive messages again press
Enter
;
- to navigate the screens use buttons
▼
,
▲
.
= VHF:ReceiveDSC =
Wait for signal
Att: 20 dB X
= VHF:ReceiveDSC =
MMSI: 413000000
Format: Individual
Categ: Safety
CRC : OK
To : 413999997.
..................
Save –F2 Prof:x
↓↑