NGT-200 USER MANUAL
NGT-200 UM.E 20210520-02
9
Test message
– if you select “Test”;
To
: 413999333
– enter the correct
MMSI code of the
DUT
(Device Under
Test).
From: 413999997
– MMSI code of the
NGT-200 by default.
Pow : -40 dBm
– power of the output
signal can be tuned with help of
+
,
–
buttons with step 10dB; recommended
power level is -50 dBm to -20 dBm.
X
– signalizes the selected measurement
configuration (same as below):
D
- direct connection
¥-
antenna
S
- Power Sensor and VSWR meter
A
- external attenuator
Measurement
configuration
can
be
selected in menu
SETTINGS / Test
config.
Press
Enter
to transmit Test message:
Repeated pressing of
Enter
will transmit DSC messages again. If necessary, output
power level can be adjusted.
To go back to menu
SEND DSC
, press
Esc
. Press
Esc
twice to enter
MAIN
MENU
.
ATTENTION
: It is necessary to enter the correct MMSI number of tested radio
station to provide the reception of the
TEST
(
Individual call
) DSC message.
Otherwise the message will be sent but not be received by this station!
== VHF:Send DSC ==
Test message
To: 413999333
From: 413999997
Pow:-40 dBm X
--- Sending ---
== VHF:Send DSC ==
Test message
To: 413999333
From: 413999997
Pow:-40 dBm X
OK !
Repeat: press ENT
== VHF:Send DSC ==
Test message
To: 413999333
From: 413999997
Pow:-40 dBm X
Send – press Enter