Page 3
INST2063 - 6/14
2.3
Return of Expired Devices
Expired P-2063 Ionizer (12 months or older) can be returned to NRD for proper disposal
according to “Return Shipping Instructions” on page 6 of this manual. A Return Authorization
(RA) is not required prior to sending a device back for disposal.
3.0
P-2063 Nuclecel
™
Ionizer
The P-2063 Nuclecel
™
Ionizer is used to neutralize static electrical charges in static sensitive
operations. The Ionizer is normally placed in an atmospheric pressure air stream so that the
airflow delivers ions generated by the Ionizer to the work area. Charged parts that are placed in
close proximity to the ion cell can also be effectively neutralized without the need of air
movement.
3.1
Installation & Operation
A.
One common method to install the P-2063 Nuclecel
™
Ionizer is by using spring
clips that will snap on to the posts of the Ionizer. The spring clips can be attached
to a mounting base. There are other methods to mounting the cell, but cannot
involve modifying the Ionizer.
Do not alter the P-2063 Nuclecel
™
in any way that may
compromise the integrity of the source. Do not drill holes,
grind or file, tap holes, etc. to the P-2063 Nuclecel
™
.
B.
Supply air movement through the ionizer to move the ions to the charged part. A
blower, fan, or compressed air/nitrogen can be used. For parts that can be placed
in close proximity (1”) from the grill openings, air movement may not be needed
to effectively neutralize the charged part.