background image

Page 1 

 

 

 

 

 

 

 

 

 

 

        INST2063 - 6/14 

1.0    Introduction 
 
Since 1969, NRD has produced ionizing radioactive sources that are used in static control, smoke 
detectors, physics research, space exploration, and instrumentation.  NRD is the world’s largest 
and one of the oldest suppliers of radioactive metallic foils.  Specially designed equipment and 
facilities enable us to produce a sealed source device that is safe and is highly effective in 
eliminating static. 
 
1.1  

Our Thanks 

 
Thank you for choosing NRD for your static control needs.  You have chosen a highly effective 
static eliminator device that is reliable, requires no calibration, and is safe.  Please review the 
information in this manual to maximize the benefit of NRD’s In-Line Ionizers. 
 
 
1.2  

Other NRD Products 

 
NRD offers static eliminator devices and accessories to eliminate or control electrostatic charges.  
The many product configurations we offer will fit a wide field of applications.  Just call us with 
your application and we can provide a solution. 
 
The electronics industry uses air ionizers to reduce product damage and loss.  Application of 
ionizers in the printing, converting and graphics industries allow in-process cleaning of product 
and faster process speeds.  Higher productivity, better quality, and enhanced reliability help 
make your company a success. 
 
Here is the range of products we offer: 

 

 

Nuclestat

®

 Bars

 offered in lengths of 4” to 142”. 

 

 

Nuclecel

 

In-Line Ionizers

 for parts blow-off and surface preparations. 

 

 

Nuclespot

™ 

Ionizer provides focused concentration of ions to the product. 

 

 

Tabletop 

Blowers

 for electronic assembly. 

 
Detailed data sheets and informational notes are available upon request.  Consult the main 
catalog for listing. 
 
 
1.3  

Customer Support 

 
Toll Free Number 

1-800-525-8076 

8:00 AM – 5:00 PM Eastern Time (M-F) 

General Listing 

1-716-773-7634 

Fax Number   

1-716-773-7744 

 

Содержание Nuclecel P-2063

Страница 1: ...63 Nuclecel Ionizer Accessories CONTENTS 1 0 Introduction Page 1 1 1 Our Thanks 1 2 Other NRD Products 1 3 Customer Support 2 0 General Information Page 2 2 1 Safety of NRD Devices 2 2 Lease Agreement 2 3 Return of Expired Devices Page 3 3 0 Model P 2063 Nuclecel Ionizer 4 0 Accessories Page 4 4 1 Model 4064 Fan 5 0 Troubleshooting Page 5 APPENDIX Data Sheet Specifications Page 6 Safety Brochure ...

Страница 2: ...or control electrostatic charges The many product configurations we offer will fit a wide field of applications Just call us with your application and we can provide a solution The electronics industry uses air ionizers to reduce product damage and loss Application of ionizers in the printing converting and graphics industries allow in process cleaning of product and faster process speeds Higher p...

Страница 3: ...bject or attempt to clean the inside of the cell Mount the ion cell in a normal way by using the mounting posts of the ion cell Do not alter the ionizer in any way i e drilling holes Contact us for mounting options Review the enclosed Safety Brochure for a more detailed description of how the ionizers work where they are typically used and the general safety of NRD ionizers 2 2 Lease Agreement All...

Страница 4: ...to the ion cell can also be effectively neutralized without the need of air movement 3 1 Installation Operation A One common method to install the P 2063 Nuclecel Ionizer is by using spring clips that will snap on to the posts of the Ionizer The spring clips can be attached to a mounting base There are other methods to mounting the cell but cannot involve modifying the Ionizer Do not alter the P 2...

Страница 5: ...the below diagram showing the installation of the P 2063 Nuclecel Ionizer Snap in the Ionizer by aligning the Ionizer posts with the spring clips The orientation of the Ionizer does not matter since it is symmetrically designed D Re assemble the front blower housing and tighten the two phillips head screws Tightening the screws will secure the ion cell inside the fan assembly E Position the Fan As...

Страница 6: ...e Action 1 Static charges are not eliminated Ion cell may be out of date and need replacement Possible oil contamination of ion cell Ions generated are being recombined before they reach the charged surface Call NRD for Ion Cell replacement Return cell to NRD for evaluation Do not attempt to clean the device Position the fan closer to the charged part 2 Fan does not turn on No power Blown fuse int...