© 2022 Genesis Attachments, LLC
Genesis GXT Mobile Shear 55
HYDRAULIC/ROTATION MAINTENANCE
Hydraulic Requirements
Operating the shear below the recommended flow and/or pressure range will adversely affect
performance and may damage the rotate motor.
Operating the shear above the recommended flow and/or pressure range may damage the
shear and its hydraulic components.
Rotation Valve Input
For cooler and more efficient hydraulic system operation, set the input pressure as indicated in the
chart below. The maximum case drain measured at the shear while rotating and cycling the jaws
must never exceed 80 PSI. Pressure increases during cold-weather operation.
Model
Flow
Pressure
115 & 225
40-60 GPM
151-227 LPM
4500-5500 PSI
310-380 Bar
335
60-90 GPM
227-340 LPM
445 - 665
70-160 GPM
264-605 LPM
775
130-240 GPM
492-908 LPM
995 & 1555
175-320 GPM
662-1211 LPM
2055 & 2555
245-320 GPM
927-1211 LPM
Model
Flow
Pressure
115 - 335
3-5 GPM
11-19 LPM
1800-2000 PSI
125-138 Bar
445 - 665
8-12 GPM
30-45 LPM
775
8-12 GPM
30-45 LPM
995
8-12 GPM
30-45 LPM
1555
13-20 GPM
49-76 LPM
2800-3000 PSI
193-207 Bar
2055
25-30 GPM
95-114 LPM
2555
35-50 GPM
132-189 LPM
Содержание Genesis GXT 665R
Страница 1: ...GXT Mobile Shear SAFETY OPERATOR S MANUAL...