© 2022 Genesis Attachments, LLC
Genesis GXT Mobile Shear
26
Inside Upper Head
Inside Excavator
7
8
9
1
Rotation Circuit - Gear Pump / Rotation Valve / Gear Motor
1
Gear Motor
2
Motor Case Drain
Do not exceed 40 PSI while operating.
3
Motion Control Valve
4
Flow Controls
5
Rotate Work Lines
Use 1/2” 3000 PSI rated hose.
6
Rotation Valve
3 position, tandem center, spring centered, with anti-cavitation
checks. Port relief settings: 2000 PSI.
7
Case Drain
Use minimum 1/2” 250 PSI rated hose (to dedicated filter).
Do not
plumb the case-drain into the main return system or into any
other existing case drain or return circuit. Plumb only to the
hydraulic tank.
8
Rotate Return Line
Use minimum 1/2” 2000 PSI rated hose (to return filter).
9
Dedicated Filter
Dedicated to case drain line only - 10 Micron
10
Gear Pump
2
3
4
5
6
10
Содержание Genesis GXT 665R
Страница 1: ...GXT Mobile Shear SAFETY OPERATOR S MANUAL...