© 2022 Genesis Attachments, LLC
Genesis GXT Mobile Shear 25
Rotation Circuit - Gear Pump / Rotation Valve / Gerotor Motor
1
Gerotor Motor
2
Motion Control Valve
3
Flow Controls
4
Rotate Work Lines
Use 1/2” 3000 PSI rated hoses.
5
Rotation Valve
3 position, tandem center, spring centered, with anti-cavitation
checks. Port relief settings: 2000 PSI.
6
Rotate Return Line
Use minimum 1/2” 2000 PSI rated hose (to return filter).
7
Gear Pump
1
2
3
4
5
6
7