82
CONNECTION OF THE HOB FOR 1774-1 – 1778-1
* calculated with the simultaneous factor following the standard EN 60 335-2-6
Caution! Be careful that the cables are correctly engaged and tightened.
Mains
Connection
Supply cord
Supply cord
Wiring diagram
Circuit braken
230 V~ 50/60 Hz
1 phase +N
3 x 4 mm
2
H 05 VV - F
H 05 RR - F
40 A *
400 V~ 50/60Hz
2 N
4 x 2,5 mm
2
H 05 VV - F
H 05 RR - F
25 A *
400 V~ 50/60Hz
3 N
5 x 1,5 mm
2
H 05 VV - F
H 05 RR - F
16 A *
230 V~ 50/60 Hz
2 phases
3 x 4 mm
2
H 05 VV - F
H 05 RR - F
40 A *
230 V~ 50/60 Hz
3 phases
4 x 2,5 mm
2
H 05 VV - F
H 05 RR - F
25 A *
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.