5.3. Camera DIP switch settings
Camera features DIP-switch blocks for configuring addresses and transmission parameters for RS-485
protocol. Switches are located under the cover located
underneath camera module.
Camera address
Protocol and speed settings
Addressing the camera
In order to avoid control conflicts, each camera should be assigned with unique address in the system.
Switches numbered 1 to 8 are responsible for assigning an address.
When building a system containing a single DVR, assign addresses in accordance with their respective
video inputs numbering.
Number visible on the DIP switch and their values are described in table below. Sum of the values
determines the physical ID address of the camera.
ATTENTION!
Each camera has its address set to 1 by default!
START-UP AND INITIAL CONFIGURATION
Switch no:
1
2
3
4
5
6
7
8
Value:
1
2
4
8
16
32
64
128
1
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
5
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
11
ON
ON
OFF
ON
OFF
OFF
OFF
OFF