ODTWARZANIE
.
ALARM INPUTS AND OUTPUTS CONNECTION
8. ALARM INPUTS AND OUTPUTS CONNECTION
NV-DVR1104/CD, NV-DVR1108/CD, NV-DVR01116/CD digital multiplexers are equipped
accordingly with 4, 8 or 16 alarm inputs, which allow to connect external devices.
When external alarm function is active (chapter 6.5) alarms will be registered in Event Registry, even if
recording mode is set to off.
In order to automatically switch the device to alarm recording mode manual or schedule recording must
be initiated.
Junction for cable connection is equipped with handy, removable clamp junctions terminal. On this
terminal also alarm output is placed. For detailed terminal description please view the image below.
PIN
FUNCTION
1
ALARM INPUT 1
2
ALARM INPUT 2
3
ALARM INPUT 3
4
ALARM INPUT 4
5
ALARM INPUT 5
6
ALARM INPUT 6
7
ALARM INPUT 7
8
ALARM INPUT 8
9
ALARM INPUT 9
10
ALARM INPUT 10
11
ALARM INPUT 11
12
ALARM INPUT 12
13
ALARM INPUT 13
14
ALARM INPUT 14
15
ALARM INPUT 15
16
ALARM INPUT 16
17
--------
18
--------
19
--------
20
GND
21
GND
22
ALARM RESET
23
ALARM OUTPUT N.C.
24
ALARM OUTPUT COM
25
ALARM OUTPUT N.O.
14
25
13
1