2.7.
Electrical connection and other rear panel elements of NDR-BA4416 DVR.
1. I/O Terminal block:
Input, output and RS-485 port .
RS-485
: two RS-485 bus ports for connecting external keyboard (K/D:
A+, B-) and PTZ cameras (P/Z: Y+, Z-)
ALARM IN:
16 alarm inputs, which may be set either as normally open
(N.O.) or normally closed (N.C.). In order to detect the alarm, signal
should last for minimum 0.5sec .
ALARM OUT(NO, COM):
Alarm relay output, max. load capacity of
the outputs is 0,5A/125VAC and 1A/30VDC.
+5V, GND:
Alarm indicator power supply, f5V
2 LAN:
RJ-45 connector port for connecting to the local network and internet.
3. USB:
USB 2.0 port for external Flash memory and mouse connection.
4. HDMI MONITOR:
Main monitor connectors, use the HDMI cable to connect to a 1080p 60Hz
(1920x1080) monitor.
5.
VGA:
Main monitor connector, VGA type. Please use signal cable provided with
the monitor when using aforementioned connection type.
6.
VIDEO OUT
:
Main monitor connectors,
7.
SPOT OUT
:
SPOT monitor output, allowing to display any camera/sequence of cameras
full screen.
8.
VIDEO IN:
16 video inputs for connecting video signal sources to the DVR.
9. AUDIO IN:
A
udio (mono) inputs for connecting microphones with pre-amplifiers
10. AUDIO OUT:
Audio out
port for connecting local speaker with pre-amplifier.
11. POWER SWITCH:
DVR power switch
.
12.
DC12V:
12V DC power socket for connecting included power adaptor.
13. FAN:
Cooling fan, do not cover!
Note: