NDR-BA2208-II, NDR-BB2208,NDR-BA2416, NDR-BA4104-II, NDR-BB4104, NDR-BA4208
and NDR-BA4416
User’s manual (short) ver.1.3
All rights reserved © AAT Holding sp. z o.o.
16
2.6.
Electrical connection and other rear panel elements of NDR-BA4208 DVR.
1.
VIDEO IN:
8 video inputs for connecting video signal sources to the DVR.
2.
VIDEO OUT
:
Main monitor connectors,
3 LAN:
RJ-45 connector port for connecting to the local network and internet.
4.
SPOT OUT
:
SPOT monitor output, allowing to display any camera/sequence of cameras
full screen.
5. USB:
USB 2.0 port for external Flash memory and mouse connection.
6.AUDIO OUT:
Audio out
port for connecting local speaker with pre-amplifier.
7.
VGA:
Main monitor connector, VGA type. Please use signal cable provided with
the monitor when using aforementioned connection type.
8. HDMI MONITOR:
Main monitor connectors, use the HDMI cable to connect to a 1080p 60Hz
(1920x1080) monitor.
9. AUDIO IN:
A
udio (mono) inputs for connecting microphones with pre-amplifiers
10. I/O Terminal block:
Input, output and RS-485 port .
RS-485
: two RS-485 bus ports for connecting external keyboard (K/D:
A+, B-) and PTZ cameras (P/Z: Y+, Z-)
ALARM IN:
16 alarm inputs, which may be set either as normally open
(N.O.) or normally closed (N.C.). In order to detect the alarm, signal
should last for minimum 0.5sec .
ALARM OUT(NO, COM):
Alarm relay output, max. load capacity of
the outputs is 0,5A/125VAC and 1A/30VDC.
GND:
Grounding
11.
DC12V:
12V DC power socket for connecting included power adaptor.
12.POWER SWITCH:
DVR power switch
.
13.FAN:
Cooling fan, do not cover!
Note:
OSD menu will be displayed on the VGA monitor by default. To switch the OSD display from VGA to
HDMI or BNC, please press and hold the ESC button for 5sec.
STARTING THE DEVICE
1
2
3
4
2
3
7
5
6 4
8
9
10
11
12
1
13