6. Needle clearance in rotary hook.
Tool:
2.0mm hexagon screwdriver.
Standard:
The distance between needle(HA-1 #14) and rotary shuttle sharp hook is 0.05
~
0.1mm
Check:
Move needle position to center by setting stitch width at
3.5
.
Adjustment:
A. Open face cover
B. Use 2.0mm hexagon screwdriver and loosen the hexagon socket screw (A) (00079206)
C. When the distance is too close, move needle bar crank (730095) forth until distance is correct.
D. When the distance is too far, move needle bar crank(730095) back until distance is correct.
E. Hexagon socket screw (A) (00079206) must be tightened and secured.