GHE-1207 Service Manual
3
1.
Presser Bar height
Tool:
2.0mm hexagon screwdriver & 6.0mm height of gauge
Standard:
Height of presser foot is 6.0mm
A. Open face cover.
B. Lift presser bar lever to upper position.
C. Loosen hexagon screw (A) of presser bar guide bracket.
D. Adjust presser bar until presser foot lifting height is 6.0mm
E. Tighten hexagon screw (A).
CHECK:
Repeat the presser bar lifter down & up for confirm the height of presser foot is 6.0mm.