GHE-1207 Service Manual
5
3. Needle drop position
Tool:
2.0mm hexagon screwdriver and flathead screwdriver.
Standard:
3.5 mm each side in the needle plate hole
when
Needle position is in the center of needle plate
hole.
Requirement of Adjustment:
Select stitch No. 006 zigzag as adjusting sample pattern, and needle will stop
in right position.
Check:
A.
Open front cover.
B.
Adjust stitch width to 3.5. (Needle is in the center)
C.
Turn manually hand wheel to make needle lower into needle plate hole, and check the distance between
needle and right side/left side in the needle plate hole.
Adjustment:
A.
Use 2.0mm hexagon screwdriver, and loosen the hexagon screw (A) of needle bar crank.
B
. Use flathead screwdriver to adjust zigzag eccentric pin until the needle is in right correct position:
When you turn it clockwise the needle is moved to right side.
When you turn it counter-clockwise the needle is moved to left side.
C
. Tighten and secure the hexagon screw (A) of needle bar crank when position is set.
-Hexagon screw (A)-000079103(4×4)
-Needle bar crank (296201)