4 RUNNING REPAIRS 

By design and operating conditions, the device belongs to the devices that should be repaired by 

specialized companies or a manufacturer.  

To submit the device to the service center (SC) for warranty service, the registration certificate of 

the device must be submitted. SC shall make a record in the registration certificate about the warranty 
service of the device and sends the copy to the manufacturer. 

The  device  shall  be  submitted  for  warranty  (after-warranty)  repair  or  verification  along  with  the 

registration  certificate  of  the  device.  The  accompanying  documents  shall  state  the  contact  details, 
phone number, and fax of the sender, and the method and address of delivery. 

The warranty repair is performed upon the presence of the filled in registration certificate. 

 

5 STORAGE 

The  storage  conditions  of  the  device  belong  to  category  1  according  to  GOST  15150  at  the 

ambient temperature from +5 °С to +40 °С and relative humidity up to 80 % at the temperature of 25 
°С. 

During short-term storage and in the periods between applications, the device shall be stored in the 

intended  packaging  container.  The  place  of  storage  should  be  free  from  vapors  of  aggressive  media 
(acids,  alkali)  and  direct  sunlight.  The  device  shall  not  be  exposed  to  rapid  shocks,  falls  or  strong 
vibrations. 

The devices shall be placed on storage racks or in palletized in the transportation container. 
For a long-term storage, the device must be preserved. 

 

6 TRANSPORTATION 

The packed devices can be transported by any kind of carrier upon the fulfilment of the following 

requirements:  

 

transportation is performed in the factory container;  

 

no direct moisture influence;  

 

the temperature does not go outside the range from -50 °С to +50 °С;  

 

humidity does not exceed 95 % at the temperature up to 35 °С;  

 

vibration is in the range 10-500 Hz with an amplitude up to 0.35 mm and acceleration up to 49 
m/c

2

 

 

shocks of peak acceleration of up to 98 m/s

2

;

 

 

the devices in the vehicle are fastened to avoid falling and mutual bumps. 

To  avoid  the  moisture  buildup  inside  the  device  after  transportation  from  the  sub-zero 

environment to a warm place, the device should be held in a container for 6 hours at room temperature.

 

 

 

7 DISPOSAL 

The device does not contain dangerous or harmful substances that could harm a human health or 

environment  and  are  not  dangerous  for  life,  public  health  and  environment  upon  expiration  of  the 
service  life.  Due  to  this  fact,  device  disposal  can  be  done  according  to  common  waste  disposal 
practice. Disposal shall be done by the type of components: plastic, metal, and fastening components. 

The  content  of  precious  metals  in  the  device  components  (electronic  boards,  connectors,  etc.)  is 

very low, so recycling is not expedient. 
 

 

Содержание UT-3K-EMA

Страница 1: ...ddress and registered address 51200 Novomoskovsk Spasskaya Str 5 Sales office landline 38 056 767 23 25 multichannel mobile 38 067 565 82 33 sales novotest com ua http novotest ua Warranty repair and...

Страница 2: ...t 7 2 4 2 Selection of the amount of coherent integration 7 2 4 3 Specifics of the operation 8 2 4 4 Replacement of the probe 8 3 Safety precautions and warranty 8 3 1 Safety precautions 8 3 2 Verific...

Страница 3: ...ormation necessary for the right product operation Before using the device you must read this manual as the device must be operated by persons acquainted with the operating principle design of the dev...

Страница 4: ...e tab 1 1 Table 1 1 Principal specifications of the device Measurement range for steel mm 2 60 Thickness measurement error mm 0 08 The permissible gap between the probe and the test object mm max 2 Th...

Страница 5: ...measured time is recalculated into the thickness value by the preset ultrasound velocity value The acoustic wave is formed by electromagnetic acoustic transduction directly on the surface of the test...

Страница 6: ...st be charged via the charger If the battery charge is less than 25 the device readings will flash on and off When the charger is connected to the device the display shows the level of the battery cha...

Страница 7: ...randomly 2 Calibrate the device if it is necessary according to c 2 3 3 Place the device on the surface of the test object The device will display the thickness value within a period from 100 millisec...

Страница 8: ...and hold the device meanwhile 4 It is recommended to put the device on the test object at a 60 angle Once the probe touches the test object the device should be put upright Throughout the device oper...

Страница 9: ...tive air humidity max 80 at the temperature 25 air pressure from 86 kPa to 106 kPa 3 2 2 Steps of the verification and accessories When performing the verification take the following steps and use acc...

Страница 10: ...10 and 60 mm reference blocks Verification is considered acceptable if the measurement error of the device for all reference blocks is not more than 0 04 mm 3 2 6 Execution of verification The verifi...

Страница 11: ...ar during the device operation However if these parts fail during the warranty period due to a defect in material or workmanship they will be repaired or replaced under the basic warranty 3 3 4 Owner...

Страница 12: ...ipping expenses the device loss of profit or damage to property all warranties shall become void if the device is officially recognized unserviceable 3 3 7 Warranties and consumer law The basic warran...

Страница 13: ...kness Gauge NOVOTEST UT 3K EMA RDC ED UT 3K EMA 000 OM Page 13 If any failure in the device is found it shall be submitted to NOVOTEST for maintenance The table 3 3 lists the failures that operator ca...

Страница 14: ...vidence Possible reason Method of elimination No digits on the display after turning on The battery is fully discharged Charge the battery When checking the performance of the thickness gauge on a ref...

Страница 15: ...ght The device shall not be exposed to rapid shocks falls or strong vibrations The devices shall be placed on storage racks or in palletized in the transportation container For a long term storage the...

Страница 16: ..._______________________________________________________________ __________________________________________________________________________________ _____________________________________________________...

Отзывы: