background image

 

 

NOVOTEST.UT-1.000 OM 

Operation manual 

Ultrasonic Thickness Gauge NOVOTEST UT-1M 

 

Page. 16 

3. SAFETY PRECAUTIONS 

3.1.  Operation thickness gauge is permitted only after reading the manual. 
3.2.  Of  minor  faults  of  the  device  is  allowed  after  it  is  turned  off,  repairs  are  carried  out 
exclusively by the manufacture.  
 

4. STORAGE AND TRANSPORTATION 

4.1.  The  device  should  be  stored  at  ambient  temperature  from  +5  to  +40  °C  and  relative 
humidity up to 80% at 25 °C. 
4.2.  The storage should be free of dust, fumes acids, alkalis and corrosive gases. 
4.3.  Transportation  of  the  device  in  case  may  be  made  by  any  mode  of  transport  in 
accordance  with  the  requirements  and  rules  of  transportation  operating  in  these  types  of 
transport. 
4.4.  During  transportation,  handling  and  storage  of  stock  the  device  should  be  kept  from 
shock, bumps and moisture.  
 

5. MAINTENANCE 

5.1.  Maintenance  of  the  device  is  made  by  the  manufacturer  in  the  event  of  faults  in  the 
device operation. 
 

6. WARRANTY 

6.1.  The manufacturer guarantees the normal operation of the unit for 12 months from date 
of purchase, and undertakes to make repair it during this time when a breakage, and failures. 
6.2.  Warranty does not apply to breaches of operation, transportation and storage conditions 
and the presence of mechanical damage to the electronic unit and transducer. 
6.3.  Warranty does not cover cables and batteries.  
 
 
 
 
Date of manufacture  

 

 

 

 

 

_________ Signature 

 
 
 
 
Sale date 

 

 

 

 

 

 

 

_________ Signature 

 
 
Notes: 
The  manufacturer  reserves  the  right  to  make  without  notice  in  the  design  of  ultrasonic 
thickness change does not impair its performance and metrological characteristics. 

 

 

Содержание UT-1M

Страница 1: ...ULTRASONIC THICKNESS GAUGE NOVOTEST UT 1M Operating Manual 2017 ...

Страница 2: ...1 9 Packagin 8 2 Intended use 9 2 1 Operational limitations 9 2 2 Preparing for use 9 2 2 1 Visual inspection 9 2 2 2 Installing the batteries 9 2 2 3 Connectiong the probe 9 2 3 Using the device 10 2 3 1 Switching on 10 2 3 2 Operation in MEASUREMENT mode 11 2 3 3 Operation in the SETTINGS mode 12 2 3 4 Operation in CALIBRATION mode 13 2 3 5 Operation in INFORMATION mode 14 2 4 Making measurement...

Страница 3: ... actions as well as information necessary for the correct use of the products Before use it is necessary to study this document as it is to be used by those familiar with the principles of operation and the design of the device Correct and effective use of the control device requires mandatory availability methods of control conditions of control incoming control methods trained and studied user m...

Страница 4: ...rmation processing unit max mm 122х65х23 Overall dimensions of the converter no more than mm 25х40 Powered by two NiMH batteries or AA batteries 1 2 V Time of continuous operation not less than h 8 Weight of electronic unit with battery less than kg 0 25 Transducer weight less than kg 0 15 Operating temperature range of the information processing unit С from 10 to 40 Operating air humidity less th...

Страница 5: ...sented in Table 1 2 Table 1 2 Metrological characteristics of converters Transducer type Measurements range Measurement error P112 10 6 2 0 8 30 mm 0 01h 0 05 mm P 112 5 10 2 1 75 mm 0 01h 0 05 mm P 112 2 5 12 2 2 5 300 mm 0 01h 0 05 mm P 112 1 25 20 2 4 300 mm 0 01h 0 05 mm where h nominal thickness mm Additional time error for 2 hours of continuous operation is no more than the basic 1 5 Parts T...

Страница 6: ...ge 9 protective silicone bumper 10 transducer 11 generator plug 12 battery compartment 13 receiver plug 14 battery compartment cover Figure 1 1 Ultrasonic thickness gauge NOVOTEST UT 1M Figure 1 2 Keyboard Buttons and Their Functions где power key Left soft key right soft key move up in the instrument menu increase the input values move down to the instrument menu decrease input values measurement...

Страница 7: ...e the correct propagation velocity of US in this particular material The actual speed of ultrasound in different materials is very different both from material to material and from the reference data The best results can be obtained if the instrument is previously calibrated using an object of a known thickness reference made of the same material as the object under study The standard should have ...

Страница 8: ...or use 2 2 1 Visual inspection Inspect the device ensure that there is no mechanical damage to the information processing unit transducer cable plugs and sockets 2 2 2 Installing the batteries Insert the batteries into the battery compartment by opening the battery cover lightly and pulling it down until the cover is completely detached The batteries are to be installed according to the polarity i...

Страница 9: ...n on Fig 2 3 Caution When disconnecting the plug from the socket grasp its housing in a corrugated area and in no case should you pull the cable Figure 2 3 Manipulating the LEMO connectors 2 3 Using the device 2 3 1 Switching on Switch the device on by a long press key on the control panel until a short time splash screen appears Figure 2 4 on the graphic display Figure 2 4 the splash screen After...

Страница 10: ...asured values DELETE ALL go to the main menu EXIT and also cancel the press and close the CANCEL selection menu 2 3 2 1 Measuring modes The device operates in several measurement modes to switch between modes use keys After it is pressed the menu for selecting the mode of operation appears NORM STAT B SCAN and CALIBER The NORM mode is intended for carrying out the usual measurement without outputt...

Страница 11: ...h Russian etc BRIGHTNESS change the brightness of the display from 0 to 100 the resolution is 10 AUTO OFF Set the device to automatically turn off when not in use off 1 5 10 30 minutes RETRO allows you to return to the measurement mode with the last measurements saved after the device is rebooted SCALE select the units of measurement mm or inch inches MATERIAL selection of the material of the obje...

Страница 12: ... keys and select the calibration for the inverter to be used 2 2 By pressing the key open the action menu with the calibrations highlight the item SELECT and confirm with the key 2 3 4 2 Creating a new inverter calibration To create a new calibration you need to 1 Using keys and select a saved calibration with the name PROBE for editing 2 Using key open the action menu with the calibrations highli...

Страница 13: ...ns in the delay lines on the result of measuring the thickness of the product it is necessary to calibrate the connected transducer before making measurements for which purpose 1 In the MEASUREMENT mode press the key And select the CALIBER mode 2 Set using the keys and The propagation velocity of the US corresponding to the reference measure on the device 6070 m s 3 Clean the contact surface of th...

Страница 14: ...owever it should be borne in mind that the thickness of the paint will go into the resulting measurement result 2 4 3 Measurements To make measurements 1 Set the speed of propagation of ultrasound in the object of control To do this go to the SETUP mode and select the material of the monitoring object in the MATERIAL parameter If the required material is not in the base of the device you need to s...

Страница 15: ... transport 4 4 During transportation handling and storage of stock the device should be kept from shock bumps and moisture 5 MAINTENANCE 5 1 Maintenance of the device is made by the manufacturer in the event of faults in the device operation 6 WARRANTY 6 1 The manufacturer guarantees the normal operation of the unit for 12 months from date of purchase and undertakes to make repair it during this t...

Страница 16: ..._________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __...

Отзывы: