1. Introduction 

This manual is designed to introducing with the instrument, principle 
of action and operation rules of Dew Point Meter NOVOTEST KTR-
1, hereinafter the Device. 
 

2. Appointment 

2.1. Dew Point Meter NOVOTEST KTR-1 is designed for rapid non-
destructive  measurement  the  temperature,  humidity,  dew  point 
calculation  and  measurement  the  surface  temperature  by  contact 
method. 
 
2.2. Dew Point Meter NOVOTEST KTR-1 allows user to measure: 

– air temperature (-20 to + 125 ° C) 
– surface temperature (-20 to + 125 ° C) 
– relative humidity 

 
and calculates: 

– dew point temperature 
– difference between dew point and surface temperature 
 

2.3.  The  Device 

can  be  used  in  workshop,  laboratory,  “field 

conditions”,  at  high-altitude  objects  and  in  other  environments 
according to the rules of safety at ambient temperatures from  -1

0 ° 

C to + 40 

° C and relative humidity up to 100%. 

 

3. Technical characteristics  

3.1. The  technical characteristics  of  Device are shown in  the  Table 
1. 

 
 
 
 

Содержание KTR-1

Страница 1: ...Dew Point Meter NOVOTEST KTR 1 OPERATING MANUAL 2015...

Страница 2: ...nd system Dew Point Meter NOVOTEST KTR 1 2 CONTENTS 1 Introduction 3 2 Appointment 3 3 Technical characteristics 3 4 Completeness 4 5 Labeling packaging 4 6 Safety precautions and maintenance 5 7 Desi...

Страница 3: ...culation and measurement the surface temperature by contact method 2 2 Dew Point Meter NOVOTEST KTR 1 allows user to measure air temperature 20 to 125 C surface temperature 20 to 125 C relative humidi...

Страница 4: ...ace temperature 1 Calculated values dew point temperature 15 40 difference between dew point and surface temperature Depends on measurements Dimensions mm 96 47 24 Operating temperature range 10 40 Po...

Страница 5: ...heavy loads and extreme temperatures Overheating can damage the screen plastic housing and internal parts Dust and prolonged high humidity can damage the unit causing malfunction The device is not wa...

Страница 6: ...KTR 1 6 Press and hold leads to on off the device Control of button illumination Long pressing leads to overturning on 180 degrees the information at the display On off of displaying of all measured p...

Страница 7: ...ntrol units and system Dew Point Meter NOVOTEST KTR 1 7 Surface temperature measurement mode Relative humidity measurement mode Dew point temperature displaying mode Displaying mode of difference betw...

Страница 8: ...For the accurate measurement of relative humidity is necessary to ensure unimpeded air flow through the grooves of the sensor 8 2 Surface temperature The sensor for measuring the surface temperature h...

Страница 9: ...r quality painting due to the formation of condensation on the surface A warning signal sounds only in the mode of displaying difference between the surface temperature and the temperature at point 9...

Страница 10: ...10 10 Warranty 10 1 The manufacturer guarantees compliance device to the technical requirements for observance of consumer terms of transportation storage and operating 10 2 Warranty period 12 months...

Отзывы: