Automatic option
During the time that the door remains open, and provided that this option is programmed in the control panel, if
the control panel or remote control is pressed, the waiting time is used up and the door is thus forced to close. If
at that very moment a safety element is activated (photocell, safety edge, etc.) the door will not close until that
safety element is released.
4.A.2 Operation of the door in “dead man control”
The “dead man” mode (or manually held-down button) is governed as follows:
The door is operated as long as the opening button is kept pressed. If the button is no longer pressed, the door
stops immediately.
To perform the closing action of the door, the closing button must be pressed and held down. If you stop pressing
the button, the door stops immediately.
Figure 12.- OPENING
Figure 13.- STOP
Figure 14.- CLOSING