NOVO 475 PRO SERIES Скачать руководство пользователя страница 7

7  

Installing Tubing Into Fittings 

Push the tube into the fitting and up to the 
tube stop  

Pull on the tube to check that it is secure. 
Test the system before use. 

Cut the tube square and remove burrs 
and sharp edges.  Ensure that the out-

side diameter is free from score marks.  
For soft or thin walled plastic tubing we 

recommend the use of a tube insert. 

Step 1

 

Step 2

 

Step 3

 

Installing Tubing Connections 

With  all  components  in  place,  complete  final  tubing 
connections using these guidelines: 

 

 

Tubing should follow contour of the cabinets 

 

Cut  tubing  to  desired  length  using  square  cuts  and 
proper cutting device 

 

Make no sharp bends 

 

Keep  tubing  from  the  post-filter  to  the  faucet  as 
short as practical for good flow. 

 

Leave enough tubing that the system can easily be 
pulled out from the cabinet for easy filter changes. 

 

Procedure (Standard Faucet) 

 
1.  Connect 3/8” tubing from faucet to RO unit. 

2.  Connect 3/8” tubing from tank to RO unit. 
3.  Connect ¼” tubing from supply valve to RO unit. 

4.  Connect ¼” tubing from drain valve to RO unit. 
5.  Check all connections to be sure they are secure. 
6.  Turn  on  feed  water  valve  and  check    for  leaks.  

(turn off and correct leaks if leaks occur). 

#1

#2

#3

#4

#5

#7

#8

#9

#6

Figure 4. Tubing Connections 

Sanitize System 

Sanitize the System (Recommended)

 

 

Sanitizing  is  recommended  immediately  after  installation  of  the  Reverse  Osmosis  system.  It’s  also  recom-
mended after servicing inner parts. It is important that the person installing or servicing the system have clean 

hands while handling inner parts of the system. 
 
1.  Turn off the water supply to the RO system and close the ball valve on the storage tank. 

2.  Open the RO faucet. 
3.  Use an eyedropper (not included) and common household bleach (5.25%). 

4.  Add  3  ml.  of  bleach  into  open  end  of  3/8  tube  connected  to  tank.    Handle  bleach  according  to  bleach 

manufacturer’s recommendations.  

5.  Connect tubing back to tank ball valve.  
6.  Sanitizing the system will be completed during the Flush System and Check Operation steps on the follow-

ing page. 

Note: The bleach must be removed from the system before drinking the water. See Flush System instructions 
on the next page. 

OPTIONAL DRAIN LINES 
(AIR GAP FAUCET) 

Содержание 475 PRO SERIES

Страница 1: ...rse Osmosis System Installation and Operation Manual 475 PRO SERIES 475BP PRO SERIES PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLING AND USING THIS SYSTEM FILTER CARTRIDGE CONFIGURATION MAY BE SUBJECT...

Страница 2: ...475 Pro Series systems use four stages of treatment to filter your water Stage 1 Remove sand dirt sediment Stage 2 Remove chlorine taste odors very fine particulates Stage 3 Reduce total dissolved min...

Страница 3: ...installed to provide the feed water for these features but you should consult your fridge owners manual for further in formation Guidelines for component placement are as follows Faucet should be plac...

Страница 4: ...vide great tasting drinking water 5 Storage Tank 3 0 Gal holds filtered water ready for use 6 Self piercing Inlet Saddle Valve is connected to the cold water line to supply water to the RO system 7 Fa...

Страница 5: ...small indent at the desired faucet location 2 flat surface is required not exceeding 1 1 4 in thickness Drill the 1 8 pilot hole Drill the hole for the faucet shank to fit through Clean up sharp edge...

Страница 6: ...e screw head out from the wall 3 Install the mounting bracket slots over the screws and hang the unit NOTE THE UNIT MUST BE INSTALLED BY HANGING THE BRACKET ON THE WALL SO THAT THERE IS NO WEIGHT ON T...

Страница 7: ...it 4 Connect tubing from drain valve to RO unit 5 Check all connections to be sure they are secure 6 Turn on feed water valve and check for leaks turn off and correct leaks if leaks occur 1 2 3 4 5 7...

Страница 8: ...e is fully closed 2 Turn storage tank valve clockwise to close 3 Open faucet to relieve pressure 4 Remove quick connect fittings from R O Membrane 5 Connect new R O Membrane 6 Turn water supply back o...

Страница 9: ...idge 2 Inlet solenoid valve not working 2 Repair or replace solenoid valve System does not shut off 1 High pressure switch not working 1 Repair or replace high pressure switch Abnormal pump cycling no...

Страница 10: ...ADDLE VALVE 10 65030027 WASTE WATER SADDLE 11 70030022 BOOSTER PUMP 475 PRO SERIES 12 70030041 TANK CUT OUT PRESSURE SWITCH 13 70030032 LOW PRESSURE SWITCH 14 70030026 TRANSFORMER 475 BOOSTER PUMP 15...

Страница 11: ...lectrical Diagrams 475 Pro Series No Pump 475BP Pro Series With Pump Wiring Diagram 475BP Pro Series With Pump TO DRAIN INLET TO DRAIN INLET PRE CARBON POST CARBON 3 0 GAL TANK PRE SEDIMENT PRE CARBON...

Страница 12: ...eriod of two 2 years from the date of manufacture or date of purchase when verified by a bill of sale Novo will replace any part which fails two 2 years from date of manufacture as indicated by the se...

Отзывы: