Installing the Self-Piercing Inlet Saddle Valve  

The self-piercing saddle valve is designed for use with 3/8” to 1/2” OD soft 
copper supply tubing. 

 
1.  Turn off cold water valve from under sink or main water line valve for 

whole house. 

2.  Before installing self-piercing valve, make sure piercing lance does not 

protrude beyond rubber gasket. 

3.  Assemble saddle valve on copper tubing. 
4.  Tighten screw to fasten saddle valve to copper tubing. 
5.  Turn  handle  clockwise  to  pierce  soft  copper  tube  until  valve  is  firmly 

seated.  (Valve is closed in this position). 

6.  Turn on water supply to pressure cold water line and check for leaks. 

Installing the Unit 

When installed under a sink the unit is normally mounted to the right or left sink cabinet sidewall.  It is sug-
gested  to  locate  the  system  where  it  can  be  easily  accessed  or  even  removed  off  the  hanging  screws  and 

pulled back out from the sink to change the filters. 
 

1.  Locate the unit in the desired position.  Make sure it is at least 3” off the floor.  Level it and mark the loca-

tion of mounting screws. 

2.  Install the screws.  Leave 1/4” of the screw head out from the wall. 

3.  Install the mounting bracket slots over the screws and hang the unit. 
 

NOTE:  THE UNIT MUST BE INSTALLED BY HANGING THE BRACKET ON THE WALL SO THAT THERE 
IS NO WEIGHT ON THE FILTERS.  THE SYSTEM IS NOT DESIGNED OR INTENDED TO SIT ON THE 

FLOOR WITH THE WEIGHT SUPPORTED BY THE REPLACEABLE FILTER CARTRIDGES.

 

Installing the Waste Water Saddle 

Prior to proceeding it  is important to inspect the condition of drain pipes 
to  make  sure  they  are  not  thin  and  frail.    Waste  water  saddles  are  de-

signed to be installed on standard 1-1/2” OD drain pipe. 
 

Install waste water saddle above (and before) the trap and on the vertical 
or horizontal tailpiece. Never install a waste water saddle close to the out-
let of a garbage disposal or plugging of the RO drain line may result .  Re-

fer to location in Figure 3. 
 

1.  Position half of the saddle with quick connect fitting at selected location 

and mark for the opening. 

2.  Drill ¼” hole at mark through one side of pipe.  Position both halves of  

the saddle on drain pipe so quick connect opening lines with hole. 

3.  Secure drain saddle clamp with bolts and nuts provided.  (Do not over 

tighten and make sure there is equal space between saddle halves on 
each side). 

Figure 2. Self-Piercing Inlet  
Saddle Valve 

Figure 3. Waste Water Saddle 

Содержание 475 PRO SERIES

Страница 1: ...rse Osmosis System Installation and Operation Manual 475 PRO SERIES 475BP PRO SERIES PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLING AND USING THIS SYSTEM FILTER CARTRIDGE CONFIGURATION MAY BE SUBJECT...

Страница 2: ...475 Pro Series systems use four stages of treatment to filter your water Stage 1 Remove sand dirt sediment Stage 2 Remove chlorine taste odors very fine particulates Stage 3 Reduce total dissolved min...

Страница 3: ...installed to provide the feed water for these features but you should consult your fridge owners manual for further in formation Guidelines for component placement are as follows Faucet should be plac...

Страница 4: ...vide great tasting drinking water 5 Storage Tank 3 0 Gal holds filtered water ready for use 6 Self piercing Inlet Saddle Valve is connected to the cold water line to supply water to the RO system 7 Fa...

Страница 5: ...small indent at the desired faucet location 2 flat surface is required not exceeding 1 1 4 in thickness Drill the 1 8 pilot hole Drill the hole for the faucet shank to fit through Clean up sharp edge...

Страница 6: ...e screw head out from the wall 3 Install the mounting bracket slots over the screws and hang the unit NOTE THE UNIT MUST BE INSTALLED BY HANGING THE BRACKET ON THE WALL SO THAT THERE IS NO WEIGHT ON T...

Страница 7: ...it 4 Connect tubing from drain valve to RO unit 5 Check all connections to be sure they are secure 6 Turn on feed water valve and check for leaks turn off and correct leaks if leaks occur 1 2 3 4 5 7...

Страница 8: ...e is fully closed 2 Turn storage tank valve clockwise to close 3 Open faucet to relieve pressure 4 Remove quick connect fittings from R O Membrane 5 Connect new R O Membrane 6 Turn water supply back o...

Страница 9: ...idge 2 Inlet solenoid valve not working 2 Repair or replace solenoid valve System does not shut off 1 High pressure switch not working 1 Repair or replace high pressure switch Abnormal pump cycling no...