Before You Start 

 

Your system contains filters which must be replaced periodically for proper operation.  (Refer to Filter 
Change Schedule on page 8.) 

 

Read all steps and guides carefully before installing and using your RO system.  Follow all steps exactly to 
correctly install. 

 

The system is designed to be used on potable water supplies only.  

If water is non-potable, additional pre-

treatment will be required.

 

 

Do not use for the treatment of water that is visually contaminated (cloudy) or has an obvious contamina-
tion source, such as contamination by raw sewage. 

 

All plumbing should be done in accordance with local codes and requirements. 

 

This system works on water pressures of 35 psi (minimum) to 100 psi (maximum).  If your house water 
pressure is over the maximum, install a pressure reducing valve in the water supply line to the filter system. 

 

Do not install the system outside, or in extreme hot or cold temperatures.  Temperature of the water supply 
to the R/O system must be between 40°F and 100°F.  Do not install on hot water. 

Tools Needed 

The following tools may be necessary, depending on the  particular installation

Your  RO  system  may  be  installed  under  the  sink,  in  a  basement,  or  other  location  depending  on  available 
space.  It is recommended the system be installed in as close a proximity to the faucet to ensure optimal sys-

tem flow rate.  If you have a water dispenser and or ice maker in your fridge, your RO system can be installed 
to provide the feed water for these features but you should consult your fridge owners manual for further in-

formation. 
 
Guidelines for component placement are as follows: 
 

Faucet 

should be placed near the sink where drinking/cooking water is normally required. A 2” flat surface is 

required  to  mount  the  faucet  if  an  existing  hole  for  a  second  faucet  is  not  available.  The  thickness  of  the 
mounting surface should not exceed 1-1/4” 
 

Storage  tank 

may be placed where it is convenient, within ten feet of the faucet. Under the sink or in a 

nearby cabinet are excellent choices. If tank is located further than ten feet from the faucet, use 1/2” tubing 

to reduce pressure drop. Full tanks may weigh more than thirty pounds, so a sturdy shelf is required. 
 

RO  unit 

may be mounted on either side of the sink, in a cabinet or heated basement, with nearby access to 

a potable, cold line and a drain. 
 

Feed  water  connection 

is accomplished with a feed water adaptor or self-piercing inlet saddle valve. Lo-

cate this assembly as close to the R/O unit as possible. Connect to a potable, cold water supply line only. 

NOTE

Softened water is preferred since it will extend the life of your R/O membrane. 

 

Drain  connection 

is accomplished using a waste water saddle valve which is designed to fit around a stan-

dard 1-1/2” OD drain pipe. The drain saddle valve should always be installed above (before) the trap and on 
the vertical or horizontal tailpiece.  

Refer to Figure 1.

 

System Location 

 

3/8” variable speed electric drill; 
1/8”, ¼”, ½” bits 

 

Center punch and hammer 

 

Phillips head and flat blade screw-
drivers 

 

Adjustable wrench 

 

Teflon tape 

 

Plastic tube cutter 

Содержание 475 PRO SERIES

Страница 1: ...rse Osmosis System Installation and Operation Manual 475 PRO SERIES 475BP PRO SERIES PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLING AND USING THIS SYSTEM FILTER CARTRIDGE CONFIGURATION MAY BE SUBJECT...

Страница 2: ...475 Pro Series systems use four stages of treatment to filter your water Stage 1 Remove sand dirt sediment Stage 2 Remove chlorine taste odors very fine particulates Stage 3 Reduce total dissolved min...

Страница 3: ...installed to provide the feed water for these features but you should consult your fridge owners manual for further in formation Guidelines for component placement are as follows Faucet should be plac...

Страница 4: ...vide great tasting drinking water 5 Storage Tank 3 0 Gal holds filtered water ready for use 6 Self piercing Inlet Saddle Valve is connected to the cold water line to supply water to the RO system 7 Fa...

Страница 5: ...small indent at the desired faucet location 2 flat surface is required not exceeding 1 1 4 in thickness Drill the 1 8 pilot hole Drill the hole for the faucet shank to fit through Clean up sharp edge...

Страница 6: ...e screw head out from the wall 3 Install the mounting bracket slots over the screws and hang the unit NOTE THE UNIT MUST BE INSTALLED BY HANGING THE BRACKET ON THE WALL SO THAT THERE IS NO WEIGHT ON T...

Страница 7: ...it 4 Connect tubing from drain valve to RO unit 5 Check all connections to be sure they are secure 6 Turn on feed water valve and check for leaks turn off and correct leaks if leaks occur 1 2 3 4 5 7...

Страница 8: ...e is fully closed 2 Turn storage tank valve clockwise to close 3 Open faucet to relieve pressure 4 Remove quick connect fittings from R O Membrane 5 Connect new R O Membrane 6 Turn water supply back o...

Страница 9: ...idge 2 Inlet solenoid valve not working 2 Repair or replace solenoid valve System does not shut off 1 High pressure switch not working 1 Repair or replace high pressure switch Abnormal pump cycling no...