AP 3.4
Performing Calibration
After the media loaded, it is necessary to do the calibration for the label size
detection.
1. Press and hold the PAUSE button.
2. Turn on the power.
3. MEDIA indicators will blink, at this point release Pause button.
4. The printer will feed the labels for 12 inches.
5. MEDIA indicators stop blinking and remain illuminated.
This procedure is very important and must always be carried out after instal-
lation and every time the media type is changed. Failure to do so will result
in the gap and label-empty detection being incorrect
.