Novenco

®

  jet fan types AUO/ARO - ARP/AUZ - AUT/ART - AZT

8

15. Warranty

Novenco provides according to law a 
standard 12 months warranty from the 
product is sent from the factory. The 
warranty covers materials and 
manufacturing defects. Wear parts are 
not covered.
Extended warranty can be agreed upon.

16. Spare parts

Contact Novenco for information about 
and ordering of spare parts.

17. Classifications

Environment

• Meet requirements for operation in 

unheated, low corrosive 
environments according to DS/EN 
ISO 12944-2

Corrosion category

• C3

Temperature ranges

• Standard: -20 to 55 °C
• Max.: -40 to 120 °C

Temperature approvals,

hot smoke fans

• Certified as F200, F300 or F400 class 

fans according to EN 12101-3 and 
tested for two hours at 300 or 
400 °C.

Balancing of rotor unit

• According to VDI 2060, DS/ISO 

21940-11:2016 class Q 6.3

Fan aerodynamic performance

• According to DS/EN ISO 

13350:2015

Sound performance

• According to ANSI/AMCA 300-14

18. Product lifetime

The fans have a product lifetime of 
20 years when they are stored, installed 
and maintained in accordance with 
Novenco’s instructions. These include 
this installation and maintenance guide.

19. Declaration of conformity

Novenco Building & Industry A/S
Industrivej 22
4700 Naestved
Denmark
hereby declares that the Novenco jet fan 
types AUO/ARO - ARP/AUZ - AUT/
ART - AZT have been manufactured in 
accordance to the below directives of the 
European Council and that they comply 
with the below standards and 
regulations.

EU directives

• Ecodesign 2009/125/EU and 

energy labelling regulation 2017/
1369/EU

• EMC 2014/30/EU
• LVD 2014/35/EU
• Machinery 2006/42/EU

UK regulations

• Ecodesign for ErP 2010 and

Energy Information 2011

• Electrical Equipment (Safety) 2016
• EMC 2016
• Supply of Machinery (Safety) 2008

Applied standards

• ANSI/AMCA 300-14
• EU regulation 327/2011
• DS 428:2019 + A1:2020 + A2:2021
• BS/DS/EN ISO 1461:2009
• BS/DS/EN 1886:2007
• BS/DS/EN ISO 5801:2017
• BS/DS/EN ISO 9001:2015
• BS/DS/EN ISO 12100:2010
• BS/DS/EN 12101-3:2015
• BS/DS/EN 12101-6:2005 + 

AC:2006

• BS/DS/EN ISO 12499:2008
• BS/DSF/FprEN ISO 12759-5:2021 

(draft)

• BS/DS/EN ISO 12944-2:2017
• BS/DS/ISO 13347-1:2004
• BS/DS/ISO 13347-2:2004
• ISO 13348:2007, class AN3
• BS/DS/EN ISO 13350:2015
• BS/DS/EN ISO 13857:2019
• BS/DS/EN ISO 14001:2015
• BS/DS/EN ISO 14118:2018
• DS/ISO/TR 14121-2:2012
• BS/ISO 14694:2003 + A1:2010
• BS/DS/EN 16798-3:2017
• BS/DS/EN ISO 20607:2019

• BS/DS/ISO 21940-11:2016

• BS/DS/ISO 21940-14:2012

• BS/DS/EN/IEC 60034-7:2020 ED3
• PD/DS/IEC TS 60034-30-2:2016
• BS/DS/EN 60204-1:2018
• BS/DS/EN IEC 61000-6-1:2019
• BS/DS/EN IEC 61000-6-2:2019
• BS/DS/EN 61000-6-3:2007 + 

A1:2011

• BS/DS/EN IEC 61000-6-4:2019
• BS/DS/EN 61800-3:2018

This declaration is valid, provided the 
product is installed, maintained and 
changed in accordance with instructions 
from Novenco Building & Industry A/S. 

UK representative

Novenco Building & Industry UK Ltd
2A Halifax Road
Bowerhill
Wiltshire
SN12 6YY
United Kingdom
Phone: +44 800 681 60 09
E-mail: [email protected]
Naestved, 01.05.2022

Peter Holt
Technical director
Novenco Building & Industry A/S 

Содержание ARO 290

Страница 1: ...Pure competence in air ENGLISH 919044 0 NOVENCO JET FAN TYPES AUO ARO ARP AUZ AUT ART AZT INSTALLATION AND MAINTENANCE ...

Страница 2: ...e g AUO 380 160 4 Serial no Fan speed Year of manufacture Weight CE marking For smoke fans also Air performance Max temperature Working period Category or class Motor nameplate information Manufacturer information Power consumption and efficiency Voltages RPMs Weight Terminal connections Documentation and instructions from the motor manufacturer are included with the fans Refer to these when perfo...

Страница 3: ...e operational conditions and the natural frequency of the foundation and supports Follow the below guidelines to avoid resonance Soft suspension Fan is fixated through springs or dampers The natural frequency Hz of thesystemshouldbeat least20 below fan speed Soft suspensions are available from Novenco Stiffsuspension Fanisfastened to a duct or a hard surface The natural frequency of this system sh...

Страница 4: ...screws from the transport brackets in the casing 4 3 Electric connection The installation and connection to the supply network must be done by authorised personnel and according to current local legislation e g the EU standard for electromagnetic compatibility EMC Electric connection 1 Check if current legislation prescribes installation of f x an emergency stop and include this in the installatio...

Страница 5: ...he fans 3 Disconnect the power supply 4 Lock the power switches Alternatively lock access to the power switches Service of the fans can now begin 6 2 Intervals Safe and proper function of the fans requiremaintenanceat regularintervals Faulty maintenance of fans covered by warranty voids the warranty Maintenanceofthefansmustincludethe following Maintenance checklist Inspection of each complete unit...

Страница 6: ...aft Press the rotor hub to contact against the motor shaft collar Leave out use of hammers or similar as the motor bearings are sensitive to shocks 4 Use a feeler gauge to check that the blade tip clearance is the same throughout the circumference Adjust the motor position in the suspension arrangement with reference to table 7 5 Connect the cable between motor and terminal box Use same routing as...

Страница 7: ...lly safe ways and in accordance to current regulations The fans and especially the electric motors contain a wide range of materials which can all be recycled Make sure worn out motors and fan parts are disassembled and recycled for the benefit of the environment 13 Patents and trademarks Novenco and are registered trademarks of Novenco Marine Offshore A S ZerAx is a registered trademark of Novenc...

Страница 8: ...o the below directives ofthe European Council and that they comply with the below standards and regulations EU directives Ecodesign 2009 125 EU and energy labelling regulation 2017 1369 EU EMC 2014 30 EU LVD 2014 35 EU Machinery 2006 42 EU UK regulations Ecodesign for ErP 2010 and Energy Information 2011 Electrical Equipment Safety 2016 EMC 2016 Supply of Machinery Safety 2008 Applied standards AN...

Страница 9: ...otor 9 Deflector AZT Outlet cone 4 Motor 10 Suspension brackets AZT Base plate 5 Motor suspension and guide vanes 11 Wire guard 6 Terminal box 12 Centre fairing Figure 6 Main components AUO ARO ARP AUZ AUT ART AZT 10 7 6 9 4 11 1 5 3 10 8 7 5 4 1 2 3 9 1 12 9 6 10 8 6 4 1 2 3 11 7 9 6 5 11 10 1 5 2 3 4 6 7 8 9 10 1 9 5 2 12 3 4 6 7 8 1 9 10 10 11 6 5 4 11 7 3 ...

Страница 10: ...4xØR D D E 6xØR H H H Ceiling mount 2xØR Fan mount 4xØR Ceiling plate AUO ARO ARP AUZ AUT ART AZT H mm D mm E mm ØR mm AUO ARO 290 320 506 560 Ø14 M12 AUO ARO 380 420 506 720 Ø14 M12 AUO 500 540 600 830 Ø14 M12 AUZ ARP 340 422 283 520 Ø14 M12 AUT ART 340 423 779 470 Ø14 M12 AZT 280 334 417 233 Ø11 M10 AZT 355 435 500 305 Ø11 M10 AZT 450 552 610 364 Ø11 M10 ...

Страница 11: ... 14 Bolts 3 Silencers 7 Rotor 11 Guide vanes 15 Washers 4 Screws 8 Set screws 12 Rivets 16 Stiffeners Figure 8 Main components Figure 9 External terminal box and connection diagram 9 10 8 7 4 5 11 12 10 9 8 7 6 5 4 10 7 6 13 4 5 15 11 14 10 16 7 6 13 4 5 15 11 14 2 3 3 3 3 2 2 1 1 1 1 Type ARO and ARP Type AUZ Type AZT Type AUO AUO ARO ARP AUZ AUT ART AZT Motor dismoun ng AUT and ART Unit dismoun ...

Страница 12: ...ct wire guards Clean the fans Clear fans and airflow ways Replace broken parts Brief on off cycle to verify rotational direction Service the fans Brief on off cycle to verify rotational direction Start up Power on fans Troubleshooting Check for abnormal sounds and vibrations Lacking performance Measure vibrations section Vibrations on page 5 Inlet or outlet blocked After 30 min operation check for...

Страница 13: ...Pure competence in air ttt EKs E Kͳ h E KD ...

Отзывы: