background image

 

 

 

 

 

 

 
 

 
 
 
 
 
 

 

 

 

 

 
 

 
 
 

 
 
 
 
 

 
 
 
 
 
 

 
 
 
 

Instruction Manual SVP IM 7 FEB 2018 

© NOVATEC, Inc. 2018 All Rights 

Reserved 

Models:  SVP-3, SVP-5 & SVP-10 

 

Silencer Positive Displacement 

Vacuum Pump 

 

Содержание SVP-10

Страница 1: ...Instruction Manual SVP IM 7 FEB 2018 NOVATEC Inc 2018 All Rights Reserved Models SVP 3 SVP 5 SVP 10 Silencer Positive Displacement Vacuum Pump...

Страница 2: ...espond to any of your requests DISCLAIMER NOVATEC Inc shall not be liable for errors contained in this Instruction Manual nor for misinterpretation of information contained herein NOVATEC shall not in...

Страница 3: ...n Valve DSV 8 7 5 Closed Loop Vacuum System 9 7 6 Ambient Air Vacuum System 9 8 ELECTRICAL INSTALLATION 10 9 STANDARD SPECIFICATIONS 3000 ft Elevation and below 16 10 OPERATING AT HIGH ELEVATIONS 3000...

Страница 4: ...er elevations and as a result the compression of air by the pump requires more work for vacuum conveying In these higher altitude applications the pressure relief valve of SVP pumps must be adjusted o...

Страница 5: ...e on delivery receipt and report immediately to trucking company 5 GENERAL INSPECTION When the unit is unpacked make a visual inspection looking for missing parts or damage that may have occurred duri...

Страница 6: ...NOVATEC Inc 2018 All Rights Reserved 6 Document SVP IM 7 FEB 2018 6 SPECIFICATIONS...

Страница 7: ...ice or in the case of an emergency Compressed Air Supply Clean compressed air should be supplied to the SVP pump s vacuum breaker valve regulator providing 80 to 120 psi A filter not supplied should b...

Страница 8: ...room Requires a separate Relief Vent in a closed system Includes 3 Bolt Coupler and pump adapter fitting For use with either VRB or SVP pumps 7 4 Closed Loop Relief Vent CLR Provides Pressure Relief i...

Страница 9: ...Loop Vacuum System 7 6 Ambient Air Vacuum System Machine Mounted Vacuum Receivers Material Selection Device Ambient Air Passes Through Vacuum Purge Valve Conveys Material Ambient Air Conveying Illustr...

Страница 10: ...ext page See FLA specification table on page 16 Connect control wiring from the conveying system control panel to the same electrical enclosure as shown on the wiring schematic for the conveying syste...

Страница 11: ...NOVATEC Inc 2018 All Rights Reserved 11 Document SVP IM 7 FEB 2018 SVP Pump Wiring 24 vdc control voltage Typical for 460 3 60 and 400 3 50...

Страница 12: ...NOVATEC Inc 2018 All Rights Reserved 12 Document SVP IM 7 FEB 2018 SVP Pump Wiring 115 vac control voltage Typical for 460 3 60 and 400 3 50...

Страница 13: ...NOVATEC Inc 2018 All Rights Reserved 13 Document SVP IM 7 FEB 2018 SVP Pump Wiring 24 vdc control voltage Typical for 575 3 60...

Страница 14: ...NOVATEC Inc 2018 All Rights Reserved 14 Document SVP IM 7 FEB 2018 SVP Pump Wiring 115 vdc control voltage Typical for 575 3 60...

Страница 15: ...nd voltage Horse Power Voltage FLA KVA SVP 3 3HP 208 3 60 9 4 3 5 230 3 60 8 5 3 5 400 3 50 5 2 3 5 460 3 60 4 3 3 5 575 3 60 3 5 3 5 SVP 5 5HP 208 3 60 14 3 5 0 230 3 60 13 0 5 0 400 3 50 7 3 5 0 460...

Страница 16: ...eric pressure is lower at higher elevations and as a result the compression of air by the pump requires more work for vacuum conveying In these higher altitude applications the pressure relief valve o...

Страница 17: ...1 Motor Starter 208V 00834 01944 01945 230V 00834 01944 01947 460V 00838 00834 00944 575V 00843 00838 00942 1 Filter Element hf 047 hf 047 hf 047 1 Regulator 50154 1 Regulator Bracket 07 1397 Lubrica...

Страница 18: ...the first week the first month and the first 3 months These inspections will be indicative of how often future maintenance will be necessary 12 1 EVERY WEEK Inspect the Filter cartridge Clean or repla...

Страница 19: ...hown on the next page and carefully examine each belt for excessive stretch looseness frayed surfaces or exposed cord Replace all belts if one or more belts are found to be excessively worn Always rep...

Страница 20: ...l Them carefully onto each sheave pulley All belts must be replaced as a set 4 Re tension the belts with the sliding motor base according to the chart below Note new belts require greater initial tens...

Страница 21: ...T OVERFILL OIL SUMPS or damage to the blower may occur 4 The oil level may naturally rise and or fall in the gauge during operation but the oil level should not fall below the middle of the site gauge...

Страница 22: ...ave There should be1 4 3 8 between the blower face and the sheave CAUTION FILL ONLY TO CENTER OF SIGHTGLASSES DO NOT OVERFILL Damage to Pump and voiding of warranty will result LUBRICATION REQUIREMENT...

Страница 23: ...note that we always strive to satisfy our customers in whatever manner is deemed most expedient to overcome any issues in connection with our equipment Warranty Periods Note All warranty periods comme...

Страница 24: ...ne has been exposed to ozone 2 NovaVac Dryer The ability of the canisters to hold vacuum will be compromised if the vacuum seal edge is damaged from mishandling We do not warranty canisters damaged fr...

Отзывы: