© NOVATEC, Inc, 2018 All Rights Reserved 22 Document: SVP IM 7 FEB 2018
13.3 Lubricant Capacities
14 SPECIAL NOTE: SHEAVE RE-INSTALLATION
CRITICAL NOTE:
On 3 and 5 Hp units, the bushing must be 1/32” – 1/16” from the blower
face.
This will result in a 5/16” between the blower face and the sheave.
On the 10 Hp, the bushing is held within the sheave. There should be1/4-3/8” between the
blower face and the sheave.
CAUTION: FILL ONLY TO CENTER
OF SIGHTGLASSES.
DO NOT OVERFILL.
Damage to Pump and voiding of
warranty will result.
LUBRICATION REQUIREMENTS
Gardner Denver AEON PD-XD Lubricating Oil.
NOVATEC P/N SVP-QT or SVP-CASE
CHANGE OIL AFTER INITIAL 100 HOURS OF
OPERATION AND EVERY
2500 HOURS THEREAFTER.
LUBRICANT CAPACITIES
GEARHOUSE LUBRICATION
Shaft Side Oil
Sump
Capacity
9.0 Oz.
9.0 Oz.
11.0 Oz.
Pump
Model
SVP-3
SVP-5
SVP-10
Gear Side Oil
Sump
Capacity
18.0 Oz.
18.0 Oz.
24.0 Oz.