9.3 Troubleshooting Chart 

 

PROBLEM 

TROUBLESHOOTING CODE 

 Power won’t come on (“POWER” light off on panel) 

A, B, C 

 No or low inlet compressed air pressure 

F, G, H, I 

 Inadequate or no process heat 

D, E, F, G, H, I, M, S 

 Material not being dried properly 

D, E, F, G, H, I, J, K, M, N, O, P, Q, R, S 

 High air dew point 

F, G, H, I, J, L,N 

 

Inlet compressed air LOWER pressure is 

less than 85 psi, as read on the pressure 

gauge supplied on the left side of the unit. 

Low inlet compressed air LOWER pressure.  Red 

light “low compressed air pressure” may be on. 

  Air inlet valve fully open? 

  Check airline to NovaDrier for obstructions 

or restrictions. 

  Is airline the correctly size per specification 

sheet on p3? 

  Are there airline “quick connects” with 

restrictive internals & check valve that is 

reducing the air pressure?  

  Check plant air system. 

Inlet compressed air LOWER temperature 

is more than 100°F 

High inlet compressed air LOWER temperature. 

Check plant air system & correct so the inlet 

temperature is below 100°F. 

Relief valve (on top of hopper) 

Clogged with material or dust. 

Clean dust out. On the ½” & ¾” npt brass 

valves on models  

N-7, N-25 & N-50: unscrew valve body & clean 

valve disk. 

Dew Point Sensor (optional feature, if 

supplied) 

Not operating: 

 

Hi or Erratic Dew Point: 

 

  Check cable & wiring for breaks or tightness. 

  Replace sensor- change yearly 

  Check for air leaks into sensor or in tubing to 

sensor. 

 
 
 
 

 

CODE 

CHECK 

CONDITIONS 

SOLUTIONS 

Power LOWER 

No voltage or incorrect voltage 

Check field installed disconnect or incoming 
voltage.  

Transformer (if supplied) 

No voltage on primary: 
No voltage on secondary: 
 

  See code “A” 

  Check fuse – if ok & power to primary, 

replace transformer 

Light bulb 

Burnt out 

Replace 

Heater amperage 

Voltage correct but amps incorrect (check both 
heaters inside box) 

Replace heater element as required 

Re-circulation air filter (located at the top 
of the box, unscrew the top wing nut to 
replace) 

Dirty filter restricting the re-circulation air flow  

Replace filter element (

replace about very 6 

month min, as required)

 

Two Compressed air inlet filters (on left 
side of box & red in color). 

One or both of the air pressure drop indicators on top 
of the filters have changed from green to red, 
indicating a clogged filter element.   

Replace both filter elements – (

Both filters 

must be replaced yearly to maintain 
warranty!).

 

Two Compressed air inlet filters (on left 
side of box & red in color). 

Condensate from one or both filters not draining from 
the automatic traps in the bottom of each filter.  This 
will cause a high dew point from the Dryer & a high 
air pressure drop across the filters.  Water shows in 
the level gauge on the side of the filter(s). 

  Check air filter drain tubing (if installed) for 

restrictions. 

  Make sure the filter is vertical. 

  Clean or replace the automatic drain, as 

required. 

Leaks in system 

Air leaking out of system causing poor performance. 

  Check piping & gasket for leaks; repair or 

replace as required. 

  Check clamp ring(s) & door clamps on 

hopper to make sure they’re tight, gaskets 
are okay & sealing properly. 

  Gate valve on material drain valve at the 

bottom of hopper on the side is fully closed 
& (2) setscrews are tight. 

  Check air tubing inside of control box to 

make sure their connected properly.  Check 
all hoses to make sure hose clamps are tight 
& hoses are not damaged. 

  Wing nut on top of round filter housing (F3) 

on top of control box is tight. 

Содержание NovaDrier ND-100

Страница 1: ...4 701 B1 Document ND IM 3 JAN 2017 NovaDrier MEMBRANE DRYER for Plastics MODELS ND 7 ND 25 ND 50 ND 75 ND 100 ND 150 ND 200 NOVATEC Inc 2017 All Rights Reserved NOTE See important information about ai...

Страница 2: ...roperly respond to any of your requests Instruction Manual ND IM 3 JAN 2017 Model ___________________________ Serial ____________________________ DISCLAIMER NOVATEC Inc shall not be liable for errors...

Страница 3: ...3 3 Condensate Drains 10 4 DESCRIPTION OF OPERATION 11 5 INITIAL START UP OPERATION 12 5 1 Turning The Dryer On 12 5 4 Other Parameters 14 6 USING THE 7 DAY TIMER OPTION 15 7 SETTING ENERGY SAVER OPTI...

Страница 4: ...rovide you with proper procedures to insure that you will be completely satisfied with your purchase Please review this manual carefully 1 1 Unpacking Caution should be exercised to make sure the equi...

Страница 5: ...ause them to loosen Inside of the hopper door the 2 perforated air diffuser tubes upper lower should be thoroughly cleaned to remove any dust moisture or oil that may have accumulated during shipment...

Страница 6: ...e sections of the hopper together are tight particularly the one at the lower part of the hopper that connects the bottom of the conical section Note that the clamp ring that attaches the hopper lid d...

Страница 7: ...ox UPPER air pressure regulator setting R2 located inside the lower part of the control box See sticker inside control box Low air pressure switch 70 PSIG 4 7 BagG Over temperature shut down set point...

Страница 8: ...TE THIS EQUIPMENT 3 2 Connecting Power Refer to the specifications in Section 2 and the mechanical and electrical drawings provided Connect the required electrical power to the unit through a main lin...

Страница 9: ...ements IMPORTANT NOTE The introduction of OZONE to the flow of compressed air will damage the membrane and void the warranty OZONE in the atmosphere near the air compressor intake can also damage the...

Страница 10: ...ot designed to remove liquid water Make sure that hazardous vapors like solvents or ozone are not being introduced into the compressed air system that is feeding the NovaDrier 3 3 3 Condensate Drains...

Страница 11: ...e hopper is controlled by a thermocouple and a solid state temperature controller located in the right side of the control box and it is the top controller labeled UPPER HEAT The rest of the compresse...

Страница 12: ...and the information in this Technical Manual Contact NOV ATEC if there are any questions about how to operate or maintain this equipment Before starting the compressed air inlet valve located on the...

Страница 13: ...int 1 Find the board behind the dew point display 2 Press HOLD one of the two white buttons 3 The display will change to the new selection 4 Release the button and the dew point readout will be in the...

Страница 14: ...point 2 While set point is displayed press to increase the set point or to reduce the set point 3 The control will revert back to display actual temperature and the dryer s heaters will respond displ...

Страница 15: ...pears Press OK 7 Press to choose hour of day for ON Press OK 8 Press to choose minutes of ON hour Press OK 9 Use to choose Mon Sun Mon Sat Mon Friday Sat Sun or single day Press OK 10 Prog 02 appears...

Страница 16: ...Heater will turn back on and if the air LOWER to the heater was OFF the air LOWER will then re open Note If the Energy Saver function cycles faster than every five minutes compressed air will never t...

Страница 17: ...e slots require the use of an SD card adaptor 3 Close the electrical box door and close the turn latches Reconnect power 4 To update the firmware turn on the machine On power up the UPPER and LOWER di...

Страница 18: ...al and ample air is supplied 85 psi as read on the pressure gauge on the side of the cabinet 2 Drain water and clean drainage tubes and or base of filters or replace both filters NOTE Visible liquid i...

Страница 19: ...on primary No voltage on secondary See code A Check fuse if ok power to primary replace transformer C Light bulb Burnt out Replace D Heater amperage Voltage correct but amps incorrect check both heat...

Страница 20: ...the set points on the label inside the box O LOWER orifice Orifice plugged with material This is a hex shaped brass fitting screwed into air inlet of LOWER heater H1 Remove the orifice clean out the p...

Страница 21: ...he compressed air LOWER system must be prevented from entering the dryer as this will permanently damage the dryer media and it may have to be replaced Every Month A Check system for air leaks or flow...

Страница 22: ...all ended wrench typically works best 5 32 will also work Remove 8 screws total 3 0 Remove the existing filter elements 4 0 Insert the new filter elements into each filter bowl and carefully refit int...

Страница 23: ...ed on top the control cabinet To check or replace this filter the system must be shut down and the filter housing should be cool to the touch Carefully remove the filter housing The filter element can...

Страница 24: ...C by the original manufacturer and then only to the extent that NOVATEC is able to enforce such warranty or guaranty NOVATEC Inc has not authorized anyone to make any warranty or representation other...

Отзывы: