              Instruction Manual ND IM 3 JAN 2017

 

Instruction Manual

 

IM ND 3 JAN 2017 

Page 10 

 

 

 

3.3.2 Connecting Compressed Air 

         Connect a clean, ozone-free, vapor-free and liquid water-free compressed air line to the 
         compressed air inlet ball valve located on the left side of the control panel.  
         

See the minimum compressed air inlet line size requirement below. 

The  

         

pressure of the compressed air to the system should be 

at least 85

 

psig but  

         not more than 125 psi

 (note that the system will run more efficiently at higher  

         air pressures).  The inlet compressed air temperature should be less that 100°F.  Note 
         that the (2) coalescing inlet compressed air filters on the NovaDrier each have an 
         internal condensate trap that is designed to remove small amounts of water droplets  
         from un-dried incoming compressed air but they are not designed to remove liquid 
         water. Make sure that hazardous vapors, like solvents or ozone, are not being 
         introduced into the compressed air system that is feeding the NovaDrier. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 
 
 
 
 

 

3.3.3 Condensate Drains 

          Connect the automatic compressed air condensate drains at the bottom of the 
          (2) compressed air filters on the side of the cabinet, so the condensate is  
          captured and disposed of properly.  If the drains are not piped away, oily water  
          may spray down periodically from the automatic drains.  Use a 1/8” npt male 
          fitting to connect into each drain. 

MODEL 

ND-7 

ND-25 

ND-50 

ND-75 

ND-100 

ND-150 

ND-200 

Minimum 

compressed air 

line size 

3/8” hose 

or 10 mm

 

3/8” hose or    

10 mm

 

3/8” hose or 

10mm

 

3/8” hose or 

10mm

 

1/2" hose 
or 12 mm

 

3/4" hose 
or 20 mm

 

3/4” hose 

or 20mm

 

Connect air 

LOWER of 85-

125 psig here

Condensate drains: 
Collect discharge or 
attach drain lines. 

See chart below 

for proper line 

compressed air 

line size for your 

dryer model, or 

the sticker

 

on 

dryer cabinet.  

 

DO NOT USE 

REDUCERS 

THAT WILL 

RESTRICT AIR

 

 

IMPORTANT

 

 

Содержание NovaDrier ND-100

Страница 1: ...4 701 B1 Document ND IM 3 JAN 2017 NovaDrier MEMBRANE DRYER for Plastics MODELS ND 7 ND 25 ND 50 ND 75 ND 100 ND 150 ND 200 NOVATEC Inc 2017 All Rights Reserved NOTE See important information about ai...

Страница 2: ...roperly respond to any of your requests Instruction Manual ND IM 3 JAN 2017 Model ___________________________ Serial ____________________________ DISCLAIMER NOVATEC Inc shall not be liable for errors...

Страница 3: ...3 3 Condensate Drains 10 4 DESCRIPTION OF OPERATION 11 5 INITIAL START UP OPERATION 12 5 1 Turning The Dryer On 12 5 4 Other Parameters 14 6 USING THE 7 DAY TIMER OPTION 15 7 SETTING ENERGY SAVER OPTI...

Страница 4: ...rovide you with proper procedures to insure that you will be completely satisfied with your purchase Please review this manual carefully 1 1 Unpacking Caution should be exercised to make sure the equi...

Страница 5: ...ause them to loosen Inside of the hopper door the 2 perforated air diffuser tubes upper lower should be thoroughly cleaned to remove any dust moisture or oil that may have accumulated during shipment...

Страница 6: ...e sections of the hopper together are tight particularly the one at the lower part of the hopper that connects the bottom of the conical section Note that the clamp ring that attaches the hopper lid d...

Страница 7: ...ox UPPER air pressure regulator setting R2 located inside the lower part of the control box See sticker inside control box Low air pressure switch 70 PSIG 4 7 BagG Over temperature shut down set point...

Страница 8: ...TE THIS EQUIPMENT 3 2 Connecting Power Refer to the specifications in Section 2 and the mechanical and electrical drawings provided Connect the required electrical power to the unit through a main lin...

Страница 9: ...ements IMPORTANT NOTE The introduction of OZONE to the flow of compressed air will damage the membrane and void the warranty OZONE in the atmosphere near the air compressor intake can also damage the...

Страница 10: ...ot designed to remove liquid water Make sure that hazardous vapors like solvents or ozone are not being introduced into the compressed air system that is feeding the NovaDrier 3 3 3 Condensate Drains...

Страница 11: ...e hopper is controlled by a thermocouple and a solid state temperature controller located in the right side of the control box and it is the top controller labeled UPPER HEAT The rest of the compresse...

Страница 12: ...and the information in this Technical Manual Contact NOV ATEC if there are any questions about how to operate or maintain this equipment Before starting the compressed air inlet valve located on the...

Страница 13: ...int 1 Find the board behind the dew point display 2 Press HOLD one of the two white buttons 3 The display will change to the new selection 4 Release the button and the dew point readout will be in the...

Страница 14: ...point 2 While set point is displayed press to increase the set point or to reduce the set point 3 The control will revert back to display actual temperature and the dryer s heaters will respond displ...

Страница 15: ...pears Press OK 7 Press to choose hour of day for ON Press OK 8 Press to choose minutes of ON hour Press OK 9 Use to choose Mon Sun Mon Sat Mon Friday Sat Sun or single day Press OK 10 Prog 02 appears...

Страница 16: ...Heater will turn back on and if the air LOWER to the heater was OFF the air LOWER will then re open Note If the Energy Saver function cycles faster than every five minutes compressed air will never t...

Страница 17: ...e slots require the use of an SD card adaptor 3 Close the electrical box door and close the turn latches Reconnect power 4 To update the firmware turn on the machine On power up the UPPER and LOWER di...

Страница 18: ...al and ample air is supplied 85 psi as read on the pressure gauge on the side of the cabinet 2 Drain water and clean drainage tubes and or base of filters or replace both filters NOTE Visible liquid i...

Страница 19: ...on primary No voltage on secondary See code A Check fuse if ok power to primary replace transformer C Light bulb Burnt out Replace D Heater amperage Voltage correct but amps incorrect check both heat...

Страница 20: ...the set points on the label inside the box O LOWER orifice Orifice plugged with material This is a hex shaped brass fitting screwed into air inlet of LOWER heater H1 Remove the orifice clean out the p...

Страница 21: ...he compressed air LOWER system must be prevented from entering the dryer as this will permanently damage the dryer media and it may have to be replaced Every Month A Check system for air leaks or flow...

Страница 22: ...all ended wrench typically works best 5 32 will also work Remove 8 screws total 3 0 Remove the existing filter elements 4 0 Insert the new filter elements into each filter bowl and carefully refit int...

Страница 23: ...ed on top the control cabinet To check or replace this filter the system must be shut down and the filter housing should be cool to the touch Carefully remove the filter housing The filter element can...

Страница 24: ...C by the original manufacturer and then only to the extent that NOVATEC is able to enforce such warranty or guaranty NOVATEC Inc has not authorized anyone to make any warranty or representation other...

Отзывы: