Instruction Manual ND IM 3 JAN 2017
Instruction Manual
IM ND 3 JAN 2017
Page 14
5.3 Changing The Drying Temperature
NOTE: The ND dryer has two heaters: UPPER and LOWER, each with its own temperature control.
Both controls must be adjusted when changing the process drying temperature.
Both displays will default to show the actual temperature.
1. Press the UPPER or LOWER temp adjustment buttons, or , once, to switch
from displaying actual drying temp, to display that heater’s set point.
2. While set point is displayed, press to increase the set point, or to reduce the set point.
3. The control will revert back to display actual temperature and the dryer’s heaters will
respond, displaying the new set point.
4. Adjust both UPPER (top) and LOWER (bottom) temperatures to the same set point value
.
5.4 Other Parameters
There are other dryer parameters that are pre-set at the factory and they should
not be changed unless directed to do so by an authorized NOVATEC Service
technician.
NOTE: The SELECT and ENTER buttons are NOT required
for changing the drying temperature.
Drying
Temperature
Adjustment
Push Buttons
UPPER HEAT
SELECT
ENTER
LOWER HEAT
SELECT
ENTER