VX16s All-in-One Controller
User Manual
www.novastar.tech
24
A
Instructions for the 3D Function
A.1 For a Single VX16s Unit
Step 1 Select a 3D video source and connect it to the DVI or HDMI connector of the VX16s unit.
Step 2 Connect the VX16s unit to the EMT200 3D emitter and the LED screen in series via Ethernet cables. Then
power on the EMT200 and turn on the shutter 3D glasses that come with the EMT200.
Step 3 Configure the screen. Please note that turning on the 3D mode will halve the output loading capacity of a
single Ethernet port and the whole unit.
Step 4 Select the 3D video source format. Select
Side-by-Side
,
Top-and-Bottom
or
Frame Sequential
according to
the actual video source format.
Step 5 Adjust the eye priority. Since the left and right eye image switching manner of the video source may not be in
sync with your shutter 3D glasses, you need to adjust the eye priority according to actual visual effect after the
3D mode is turned on. The default option is
Left
.
Step 6 Adjust the right eye start.
For a side-by-side 3D video source
If the resolution of the video source is 1920×1080@60Hz, set the right eye start to 960. If the resolution of
the video source is 3840×1080@60Hz, set the right eye start to 1920. In conclusion, it is recommended
you set the right eye start to the half of the video source width.
For a top-and-bottom 3D video source
If the resolution of the video source is 1920×1080@60Hz, set the right eye start to 540. If the resolution of
the video source is 3840×1080@60Hz, set the right eye start to 540. In conclusion, it is recommended you
set the right eye start to the half of the video source height.
For a frame-sequential 3D video source, you do not need to adjust this parameter.
Step 7 Adjust the signal delay to keep the left-right eye switching of the 3D glasses and the LED screen in sync. It is
recommended you adjust the signal delay according to the actual visual effect after the 3D mode is turned on.
Step 8 Turn on the 3D mode. Then only the main layer is kept and other layers are closed.
Step 9 Wear your 3D glasses to enjoy the 3D effect. No matter how the main layer size or position is adjusted, the 3D
effect will not be affected at all.
A.2 For Multiple VX16s Units
Step 1 Select a 3D video source and connect it to the DVI or HDMI connectors of all the VX16s units.
Step 2 Connect all VX16s units to the LED screen via Ethernet cables, and connect the EMT200 to one of the units
via an Ethernet cable. Then power on the EMT200 and turn on the shutter 3D glasses that come with the
EMT200.
Step 3 Configure the area of the screen loaded by each unit. Please note that turning on the 3D mode will halve the
output loading capacity of a single Ethernet port and the whole unit.
Step 4 Set the image mosaic parameters of each unit, which will not be detailed in this document.
Step 5 Select the 3D video source format for all the units. Select
Side-by-Side
,
Top-and-Bottom
or
Frame
Sequential
according to the actual video source format. Set the same video source format for all the units.
Step 6 Adjust the eye priority for all the units. Since the frame-sequential manner of the video source may not be in
sync with your shutter 3D glasses, you need to adjust the eye priority according to actual visual effect after the
3D mode is turned on. The default option is
Left
. Set the same eye priority for all the units.
Step 7 Set the same right eye start for all the units.
For a side-by-side 3D video source
If the resolution of the video source is 1920×1080@60Hz, set the right eye start to 960. If the resolution of
XI'AN
NOVASTAR
TECH
CO.,LTD.