JADAK JE-238
User’s Manual
Page 26
Good Read Delay
This sets the time period before the JE-238 can read another bar code.
Several commonly used Good Read Delay-menu command barcodes are included below.
Default time = 0 Seconds.
Note:
Good Read Delay is most effective when in Presentation Mode or when Multiple Symbol
Mode is turned on in combination with another Trigger Mode.
Setting examples:
* No Good Read delay
Good Read delay 0.2 seconds
Good Read delay 0.5 seconds
Good Read delay 1.0 seconds
Good Read delay 2.0 seconds
Good Read delay 5.0 seconds
If a different delay time other than those provided is needed, it can either be set by sending the
serial command
DLYGDRD
x
(where ‘x’ is a value between 0 and 30000)
, to set the time
between 0 (no delay) and 30000 (=30 sec.) in steps of 1millisecond, or by scanning the barcode
below, then set the delay by scanning the digit codes and the SAVE barcode in
Please contact JADAK if assistance is needed.
User Specified Good-read Delay