4.3. Installing
4. Preparing for use
4.3.18.2. MODEL ASC-6 V41
TARGET AUDIENCE AND QUALIFICATION
Experts
REQUIREMENTS
Table 4.20.: ASC-6 V41: Mains supply
Characteristic
Specification
Voltage; frequency; power for
Model ASC-6 V41 WFI L200
90–264 V; 47–63 Hz; max. 2350 W
PROCEDURE
1. Ground the frame by the M5 bolt that can be found next to the mains
supply connector. The grounding bolt is labeled by .
2. Connect the ASC according to the specification via its mains supply con-
nector to the mains supply.
The ASC will boot as soon as it is connected to mains supply.
SPECIFICATION OF THE MAINS SUPPLY CONNECTOR
• Labeled: –
• Cable length: typ. 5 m
• Cable cross section: 2.5 to 8 mm²
64