4. Preparing for use
4.3. Installing
Pin
Name
Description
Digital inputs:
galvanically isolated; sampling frequency
100 kHz; low < 66 % and high > 82 % (e. g. signal thresh-
old at 15 V: low = 9.90 V and high = 12.30 V)
2
Reserved
Do not connect
3
Reserved
Do not connect
4
Reserved
Do not connect
5
Reserved
Do not connect
Digital outputs:
galvanically isolated, short circuit proof
with integrated flyback circuit, high-side driver, output
current source max. 150 mA continuous (500 mA peak),
sink not specified
6
Reserved
Do not connect
7
Reserved
Do not connect
8
Reserved
Do not connect
9
Reserved
Do not connect
S
GGND
Frame ground
SIGNAL DESCRIPTION
JOB_START_IN
starts the job and continues the job respectively, if
the job is paused
JOB_ABORT_IN
aborts the job immediately and activates the
JOB_FAILED_OUT signal
SAFE_REQUEST_IN
tries to set all managed devices to the power
state
Armed
. With a laser device, this is the state where the
GATE signal and the MOD signal are deactivated.
ATTENTION_IN
tries to set all managed devices to the power state
Ready
and keeps them in this state even if e. g. a power saver
is active
JOB_READY_OUT
indicates the job is selected and ready for the
JOB_START_IN signal
ASC_ARGNET-series_manual, 2022-02-15
47
Содержание ARGNET ASC-1
Страница 6: ...Contents A 5 Declaration of conformity 99 vi ASC_ARGNET series_manual 2022 02 15...
Страница 10: ......