4
SPECIFICATIONS
225-HMP60x Temperature and Relative Humidity Sensor
Humidity sensor
Vaisala INTERCAP® (replaceable)
Measurement Range
0 to 100% RH
Typical accuracy:
±3 %RH (0 … 90 %RH)
±5 %RH (90 … 100 %RH)
at −40 … 0 °C and +40 … +60 °C
±5 %RH (0 … 90 %RH)
(−40 … +32 °F and +104 … +140 °F)
±7 %RH (90 … 100 %RH)
Temperature sensor
1000 ohm platinum resistive element (RTD)
Measurement range
−40 … +60 °C (−40 … +140 °F)
Accuracy:
at +10 … +30 °C (+50 … +86 °F)
±0.5 °C (±32.9 °F)
at −40 … +10 and +30 … +60 °C
(−40 … +50 and +86 … +140 °F)
2 channels
HMP60A
: 0 … 1 VDC
HMP60C
: 0 … 5 VDC
Start-up time
4 seconds
External loads
HMP60A
: RL min. 10 kΩ
HMP60C
: RL min. 50 kΩ
Accuracy at +20 °C (+68 °F)
±0.2 % of FS
Temperature dependence
±0.01 % of FS/°C (±0.006 % of FS/°F)
Power consumption
1 mA average, max. peak 5 mA
Operating voltage
HMP60A
: 5 … 28 VDC
HMP60C
: 8 … 28 VDC
Operating temperature
−40 … +60 °C (−40 … +140 °F)
IP rating
IP65
EMC compliance
EN 61326-1, industrial environment
Regulatory compliance
CE, ROHS Directive, EMC Directive
Probe body
Stainless steel (AISI 316)
Probe filter
Chrome coated ABS plastic (replaceable)
Probe connector
4-pin M8 (IEC 60947-5-2)
Cable
Polyurethane or FEP, 12 inch (30 cm), tinned leads
Size
0.47" Dia (12 mm) x 3" L (80 mm), threaded M12 x 1
Weight / Shipping
1 oz (28 g) / 0.4 lb (182 g)
Operating environment
Mechanical
±0.6 °C (±33.08 °F)
at 0 … +40 °C (+32 … +140 °F)
Relative Humidity
Temperature
Analog outputs
Power requirements