Receiving and Unpacking

 

 

Carefully unpack all components and compare to the packing list. Notify NovaLynx Corporation 
immediately concerning any discrepancy. Inspect equipment to detect any damage that may have 
occurred during shipment. In the event of damage, any claim for loss must be filed immediately with 
the carrier by the consignee. Damages to equipment sent via Parcel Post or UPS require the consignee 
to contact NovaLynx Corporation for instructions. 

 

Returns

 

 

If equipment is to be returned to the factory for any reason, call NovaLynx between 8:00 a.m. and 4:00 
p.m. Pacific Time to request a Return Authorization Number (RA#). Include with the returned 
equipment a description of the problem and the name, address, and daytime phone number of the 
sender. Carefully pack the equipment to prevent damage or additional damage during the return 
shipment. Call NovaLynx for packing instructions in the case of delicate or sensitive items. If packing 
facilities are not available take the equipment to the nearest Post Office, UPS, or other freight service 
and obtain assistance with the packaging. Please write the RA# on the outside of the box. 

 

Warranty

 

 

NovaLynx Corporation warrants that its products are free from defects in material and workmanship 
under normal use and service for a period of one year from the date of shipment from the factory. 
NovaLynx Corporation's obligations under this warranty are limited to, at NovaLynx's option: (i) 
replacing; or (ii) repairing; any product determined to be defective. In no case shall NovaLynx 
Corporation's liability exceed product's original purchase price. This warranty does not apply to any 
equipment that has been repaired or altered, except by NovaLynx Corporation, or that has been 
subjected to misuse, negligence, or accident. It is expressly agreed that this warranty will be in lieu of 
all warranties of fitness and in lieu of the warranty of merchantability. 

 

Address

 

 

NovaLynx Corporation 
431 Crown Point Circle, Suite 120 
Grass Valley, CA 95945-9531 USA 
Phone: (530) 823-7185 
Email: [email protected] 
Website: www.novalynx.com

 

 

Copyright © 1988-2021 by NovaLynx Corporation

 

 

Содержание 210-421W-A

Страница 1: ...x A User Manual Dual Set Point Temperature Alarm 210 421 A Air Temperature 210 421W A Water Soil Temperature Air Temperature Sensor Water and Soil Temperature Sensor Phone 530 823 7185 Email nova nova...

Страница 2: ...ns in the case of delicate or sensitive items If packing facilities are not available take the equipment to the nearest Post Office UPS or other freight service and obtain assistance with the packagin...

Страница 3: ...P Button 6 4 2 3 DOWN Button 7 4 2 4 CLEAR Button 7 4 2 5 GO Button 7 4 3 Program Alarm Thresholds 7 4 4 Program Alarm Delays 8 4 5 DIP Switch Settings 8 5 TEMPERATURE SENSOR INSTALLATION 9 5 1 Air Te...

Страница 4: ...the unit is programmed by push button controls without the need to connect a computer All set points and the minimum and maximum temperatures are stored in non volatile memory DIP switch settings sele...

Страница 5: ...connectors supplied Relay specifications Form C SPDT N O and N C Contact rating 3A 24Vdc 115 VAC Alarm ON OFF delay range 0 to 99 seconds Timing accuracy 2 Measurement range 40 to 160 F 40 to 60 C In...

Страница 6: ...tion 4 2 Menu Navigation The programming buttons are below the display 4 2 1 MENU Button Press the MENU button One of three sub menus will be displayed depending on which was viewed last Additional us...

Страница 7: ...te to the Temp Alarms menu 1 Press GO until the display shows the operating mode screen see GO Button above 2 Press MENU to bring up one of the three sub menu displays 3 Press UP to reach the Temp Ala...

Страница 8: ...creen 4 5 DIP Switch Settings The DIP switches are pre set at the factory and should not need to be adjusted However sometimes during installation they get changed accidentally 1 The Dual Set Point co...

Страница 9: ...t is on the underside of the bracket The clamp will provide strain relief for the cable and ensure the sensor will not fall out For Pipe Mounting 1 Remove the U bolt from the mounting bracket 2 Secure...

Страница 10: ...AC receptacle for power If the controller is inside a building the sensor cable may need to be routed outside so that the sensor can be exposed ambient air conditions 6 2 Controller Mounting There are...

Страница 11: ...of this wire to a good earth ground an electrical box with an earth connection or a metal cold water pipe that actually enters the ground Failure to provide a ground may cause erratic operation and ma...

Страница 12: ...u have programmed the temperature alarm to the settings you desire and the temperature alarm system is operating properly before you connect power to your external devices 8 ALARM FUNCTIONS The temper...

Страница 13: ...Go PROGRAMMING BUTTONS MODE WIND UNITS TEMP UNITS BUZZER WIND MPH DEG F BUZZ TEMP KPH DEG C SILENT ON OFF Wt Wu Tu Si DIP SETTINGS DUAL SET POINT TEMPERATURE ALARM 210 421 A and 210 421W A Alarms OFF...

Отзывы: